5.1.4.2.
Tonal Signal
This Service Mode is used to check the tonal signal output. Signals can be output to the line using the
following procedure.
Tonal Signal Table
Service Mode 4 - Tonal Signal
Step
Operation or Unit Condition
LCD Display
1
Standby
2
Press “FUNCTION” and then “7”.
3
Press “MONITOR” four times, then press “*”.
4
Press “4”.
5
Press “2” and “START”.
6
Enter the signal number (1-7) to select the binary
signal.
7
Press "CLEAR" to end the signal generation. To select
another signal, repeat step 6.
8
Press "STOP" twice to return to standby.
Number
Signals
1
462 Hz
2
1080 Hz
3
1100 Hz
4
1300 Hz
5
1650 Hz
6
1850 Hz
7
2100 Hz
MMM-dd-yyyy 15:00
00%
SET MODE (1-6)
ENTER NO. OR
SERVICE MODE
ENTER NO. OR
MODEM TEST (1-5)
1:SIGNAL TEST
TONAL TEST
IDLE (ENTER 1-7)
TONAL TEST
1080Hz
TONAL TEST
IDLE (ENTER 1-7)
MMM-dd-yyyy 15:00
00%
Summary of Contents for Facsimile UF-590
Page 17: ...17 1 4 Control Panel For USA and Canada UF 790 UF 780 790 780 ...
Page 18: ...18 For Other Destinations UF 590 UF 580 ...
Page 27: ...27 10 Remove 2 P6A Bushings 316 11 Remove the Eject Roller 303 10 11 ...
Page 33: ...33 11 Remove 2 Screws 4N 12 Remove the Paper Feed Rollers 518 11 12 ...
Page 294: ...294 4 3 2 1 D C B A 1 2 3 4 Drawing Name HVPS 2 4 Model UF 580 590 780 790 ...
Page 295: ...295 4 3 2 1 D C B A 1 2 3 4 Drawing Name HVPS 3 4 Model UF 580 590 780 790 ...
Page 296: ...296 4 3 2 1 D C B A 1 2 3 4 Drawing Name HVPS 4 4 Model UF 580 590 780 790 ...
Page 297: ...297 4 3 2 1 D C B A 1 2 3 4 Drawing Name LVPS 1 1 Model UF 580 590 780 790 ...
Page 298: ...DZZSM00158 ...