155
Note:
If an 021 series Error Code occurs, 021-25 (Thermistor Open) or 021-26 (Thermistor detected
temperature over 392
°
F (200
°
C), a pre-programmed recovery safety software is activated to protect the
unit and the service personnel during abnormal increase in temperature.
Once activated, this program is downloaded into the LPC PC Board’s SRAM, disabling the Fuser Lamp
and preventing it from turning ON again.
In order to reset this circuit, please follow the procedure below.
1) Reset the LBP Fuser by using Service Mode 7-1-2 (Section 5.1.7.) and Power OFF/ON.
2) Replace the Thermistor or Fuser Unit. If the problem persists.
3) Replace the SC PCB.
64 Unit detected “No Cassette”.
1. Cassette not installed or partially open.
2. Cassette Sensor defective.
65 Unit detected “Out of Paper”.
1. The Paper Cassette is empty.
2. Paper Detect Sensor defective.
81 No response from LP Controller.
1. SC PCB defective.
82 Illegal response from LP Controller.
1. SC PCB defective.
Error
Code
Description of Problems
Cause
Summary of Contents for Facsimile UF-590
Page 17: ...17 1 4 Control Panel For USA and Canada UF 790 UF 780 790 780 ...
Page 18: ...18 For Other Destinations UF 590 UF 580 ...
Page 27: ...27 10 Remove 2 P6A Bushings 316 11 Remove the Eject Roller 303 10 11 ...
Page 33: ...33 11 Remove 2 Screws 4N 12 Remove the Paper Feed Rollers 518 11 12 ...
Page 294: ...294 4 3 2 1 D C B A 1 2 3 4 Drawing Name HVPS 2 4 Model UF 580 590 780 790 ...
Page 295: ...295 4 3 2 1 D C B A 1 2 3 4 Drawing Name HVPS 3 4 Model UF 580 590 780 790 ...
Page 296: ...296 4 3 2 1 D C B A 1 2 3 4 Drawing Name HVPS 4 4 Model UF 580 590 780 790 ...
Page 297: ...297 4 3 2 1 D C B A 1 2 3 4 Drawing Name LVPS 1 1 Model UF 580 590 780 790 ...
Page 298: ...DZZSM00158 ...