129
408
XMT
D
Transmitter received RTN after it
transmitted EOP, MPS, or EOM.
Receiver receives data with error. (Line
quality is poor)
Receiver is defective. (Modem, etc.)
SC PCB or MJR PCB are defective.
409
XMT
D
Transmitter receives PIN after it
transmitted a post message, such
as EOP, MPS, EOM, etc.
Receiver receives data with error due to
poor line quality, and receiving operator
requests voice contact.
Receiver is defective. (Modem, etc.)
SC PCB or MJR PCB are defective.
410
RCV
D
Received DCN while waiting for
post command. (EOP, MPS, EOM,
etc.)
Interface or line is faulty.
Transmitter is defective.
411
RCV
(Polling)
B
Received DCN after transmitting
NSC.
Transmitter is not ready for polling
communication.
Password does not match between
transmitter and receiver.
412
G3 RX
B, D
No response within 12 seconds in
NSS/DCS/MPS wait state. (After
transmitting FTT)
Transmitter is defective.
SC PCB is defective.
414
RCV
(Polling)
B
No response received after
transmitting 3rd NSC.
Password does not match between
transmitter and receiver.
Transmitter is defective. (No original,
document jam, etc.)
415
XMT
(Polling)
B
Remote side attempted to receive
message from your machine in
polling communication.
Inform the remote side that your
machine does not have the polling
transmission feature.
416
RCV
D
Receiver did not detect post
command, such as EOP, MPS,
EOM, etc.
Transmitter is defective.
Line quality is poor. (RTC signal is
distorted due to line noise)
SC PCB or MJR PCB are defective.
417
RCV
C
Receiver returned RTN in
response to post message.
Line quality is poor. (There are
excessive errors in received data)
SC PCB or MJR PCB are defective.
418
RCV
C
Receiver transmitted PIN in
response to PRI-Q from
transmitter. (Transmitting operator
requests voice contact)
Line quality is poor. (There are
excessive errors in received data)
SC PCB or MJR PCB are defective.
420
RCV
B
T1 timer (35 sec.) elapsed without
detecting 300 bps signal.
There is wrong incoming call.(non-
facsimile communication)
Transmitter is defective.
SC PCB or MJR PCB are defective.
421
RCV
B
Busy Tone is detected after
sending NSF Signal.
Remote station disconnected the line.
Wrong number is dialed.
422
XMT
B
Content of NSF (or DIS) or NSC
(or DTC) was invalid.
There is an incompatibility.
427
G3
RCV
B
DCN received to NSF/CSI/DIS
transmitted.
The interface is incompatible.
433
XMT
RCV
B, D
T.30 Protocol abnormal.
Defective remote station.
Fax Information Codes
Code
Mode
Phase
Description of Problem
Cause
Summary of Contents for Facsimile UF-590
Page 17: ...17 1 4 Control Panel For USA and Canada UF 790 UF 780 790 780 ...
Page 18: ...18 For Other Destinations UF 590 UF 580 ...
Page 27: ...27 10 Remove 2 P6A Bushings 316 11 Remove the Eject Roller 303 10 11 ...
Page 33: ...33 11 Remove 2 Screws 4N 12 Remove the Paper Feed Rollers 518 11 12 ...
Page 294: ...294 4 3 2 1 D C B A 1 2 3 4 Drawing Name HVPS 2 4 Model UF 580 590 780 790 ...
Page 295: ...295 4 3 2 1 D C B A 1 2 3 4 Drawing Name HVPS 3 4 Model UF 580 590 780 790 ...
Page 296: ...296 4 3 2 1 D C B A 1 2 3 4 Drawing Name HVPS 4 4 Model UF 580 590 780 790 ...
Page 297: ...297 4 3 2 1 D C B A 1 2 3 4 Drawing Name LVPS 1 1 Model UF 580 590 780 790 ...
Page 298: ...DZZSM00158 ...