36
EN
UTILITY MENU (u + NUMBER)
(cont.)
u5
Automatic Rotation Stop Setting
Rotation can be stopped automatically
after the set time has passed.
This is effective in a process where it
is necessary to stop rotation without
snugging screws or in a process where
there is a concern about the penetration
of long screws due to screw mix-ups.
•
The upper limit of the rotation time
should be set in “
u4 Rotation Time-
based Detection Setting”.
P. 35
•
When the rotation time reaches its
upper limit, rotations stop without
clutch activation. Screw fastening is not
detected, and the detection lamp does
not light up.
Also, no work data history is retained.
When it is set to “_1”
* The upper limit is set to 0.6 in “
u4
Rotation Time-based Detection
Setting”.
Rotation stops when the rotation time
before snugging reaches 0.6 s.
0.6 s
0.0 s
Rotation
stop
Screw
fastening start
■
Setting Procedure
Switch to setting mode.
Set the forward/reverse lever to
the trigger switch lock position, and
hold down the OK button.
P. 22
Choose “u5” by pressing
the ▲ and ▼ buttons, and
press the OK button.
A set value appears on the display.
Select a desired one by
pressing the ▲ and ▼
buttons.
The default is “_ _”.
Display
Automatic Rotation
Stop
OFF
ON
Press the OK button to
confirm it.
When the setting is completed, a
buzzer sounds long (a long beep),
and the display returns to the menu
screen.
The upper limit of the rotation time
should be set in “ u4 Rotation
Time-based Detection Setting”.
Back to Operation Mode.
Hold down the OK button.
P. 22
EY9310ADA202.indb 36
EY9310ADA202.indb 36
2023/12/07 19:02:01
2023/12/07 19:02:01
Summary of Contents for EYADA Series
Page 4: ...CN 4 EY9310ADA202 indb 4 EY9310ADA202 indb 4 2023 12 07 19 01 39 2023 12 07 19 01 39...
Page 5: ...CN 5 Panasonic EY9310ADA202 indb 5 EY9310ADA202 indb 5 2023 12 07 19 01 39 2023 12 07 19 01 39...
Page 6: ...CN 6 EY9310ADA202 indb 6 EY9310ADA202 indb 6 2023 12 07 19 01 39 2023 12 07 19 01 39...
Page 7: ...CN 7 EY9310ADA202 indb 7 EY9310ADA202 indb 7 2023 12 07 19 01 39 2023 12 07 19 01 39...
Page 8: ...CN 8 50 EY9310ADA202 indb 8 EY9310ADA202 indb 8 2023 12 07 19 01 39 2023 12 07 19 01 39...
Page 9: ...CN 9 EY9310ADA202 indb 9 EY9310ADA202 indb 9 2023 12 07 19 01 39 2023 12 07 19 01 39...
Page 11: ...CN 11 OK EY9310ADA202 indb 11 EY9310ADA202 indb 11 2023 12 07 19 01 40 2023 12 07 19 01 40...
Page 51: ...CN 51 EY9310ADA202 indb 51 EY9310ADA202 indb 51 2023 12 07 19 01 49 2023 12 07 19 01 49...
Page 53: ...CN 53 P 35 EY9310ADA202 indb 53 EY9310ADA202 indb 53 2023 12 07 19 01 50 2023 12 07 19 01 50...
Page 116: ...58 MEMO EY9310ADA202 indb 58 EY9310ADA202 indb 58 2023 12 07 19 02 04 2023 12 07 19 02 04...
Page 117: ...59 MEMO EY9310ADA202 indb 59 EY9310ADA202 indb 59 2023 12 07 19 02 04 2023 12 07 19 02 04...
Page 118: ...60 MEMO EY9310ADA202 indb 60 EY9310ADA202 indb 60 2023 12 07 19 02 04 2023 12 07 19 02 04...