8 - ENGLISH
Attention
z
To prevent obstruction of the intake and exhaust vents, install the projector with a clearance from walls and objects. For details about the
required distance from surrounding walls and objects, refer to the operating instructions for your projector. If you are installing the projector
in a sealed space, be sure to provide additional air conditioning equipment and ventilation equipment. Insufficient ventilation will result in an
accumulation of heat and may activate the projector’s protection circuit.
z
Avoid setting up in places which are subject to sudden temperature changes, such as near an air conditioner or lighting equipment (studio
lamps, etc.).
■
Dimensional relationship
To use a projected image size not listed in the tables, check the projected image size SD (m) and calculate the
value using the formulas provided in “Formulas for calculating dimensions” (
x
page 9).
<For
PT-CMZ50>
Dimensions in the tables are values when Digital Zoom Extender function is disabled by setting the [POSITION]
menu → [SCREEN ADJUSTMENT] → [DIGITAL ZOOM EXTENDER] to [OFF] on the projector.
(Unit: m)
Projected image size
(Aspect ratio 16:10)
L
L1
H1
*1
H2
*1
SD
SH
SW
2.03 (80")
1.077
1.723
0.41
0.010
0.346
0.519
2.16 (85")
1.144
1.831
0.43
0.033
0.358
0.531
2.29 (90")
1.212
1.939
0.46
0.055
0.370
0.543
2.41 (95")
1.279
2.046
0.48
0.078
0.381
0.554
2.54 (100")
1.346
2.154
0.50
0.10
0.393
0.566
2.79 (110")
1.481
2.369
0.55
0.15
0.417
0.590
3.05 (120")
1.615
2.585
0.59
0.19
0.441
0.614
Projected image size
(Aspect ratio 16:9)
L
L1
H1
*1
H2
*1
SD
SH
SW
2.03 (80")
0.996
1.771
0.42
0.020
0.407
0.580
2.16 (85")
1.058
1.882
0.44
0.043
0.422
0.595
2.29 (90")
1.121
1.992
0.47
0.067
0.438
0.611
2.41 (95")
1.183
2.103
0.49
0.090
0.453
0.626
2.54 (100")
1.245
2.214
0.51
0.11
0.469
0.642
2.79 (110")
1.370
2.435
0.56
0.16
0.500
0.673
3.05 (120")
1.494
2.657
0.61
0.21
0.532
0.705
Projected image size
(Aspect ratio 4:3)
L
L1
H1
*1
H2
*1
SD
SH
SW
1.78 (70")
1.067
1.422
0.41
0.007
0.344
0.517
1.91 (75")
1.143
1.524
0.43
0.032
0.358
0.531
2.03 (80")
1.219
1.626
0.46
0.058
0.371
0.544
2.16 (85")
1.295
1.727
0.48
0.083
0.384
0.557
2.29 (90")
1.372
1.829
0.51
0.11
0.398
0.571
2.41 (95")
1.448
1.930
0.54
0.13
0.411
0.584
2.54 (100")
1.524
2.032
0.56
0.16
0.425
0.598
2.79 (110")
1.676
2.235
0.61
0.21
0.451
0.624
*1 Values in the tables are based on the factory default height position of the arm.
Installation dimensions (ET-WBC100) (continued)