ENGLISH
–
105
Special Featur
es
Using the PJLink™ protocol
The network function of the projector supports PJLink™ class 1, and the PJLink™ protocol can be used to
perform projector setting and projector status query operations from a PC.
Supported commands
The following table lists the PJLink™ protocol commands that can be used to control the projector.
Command
Control details
Notes
POWR
Power supply control
Parameters
0 = Standby
1 = Power ON
POWR ?
Power supply status query
Parameters
0 = Standby
1 = Power ON
2 = Cool-down in progress
3 = Warm-up in progress
INPT
Input selection
Parameters
11 = RGB1
12 =RGB2
21 = VIDEO
22 = S-VIDEO
31 = DVI-D
32 = AUX (only enabled if ET-MD77DV, ET-MD77SD1, ET-MD77SD3 or
ET-MD100SD4 is installed)
INPT ?
Input selection query
AVMT
Shutter control
Parameters
30 = Shutter mode off (picture mute cancelled)
31 = Shutter mode on (picture mute)
AVMT ?
Shutter mode query
ERST?
Error status query
Parameters
1st byte:
Indicates fan errors, range 0--2
2nd byte:
Indicates lamp errors, range 0--2
3rd byte:
Indicates temperature errors, range 0--2
4th byte:
Indicates cover open errors, range 0--2
5th byte:
Indicates filter errors, range 0--2
6th byte:
Indicates other errors, range 0--2
Definitions for each value from 0 to 2 are as follows.
0 = No error known
1 = Warning
2 = Error
LAMP ?
Lamp status query
Parameters
1st digits (1--5 digits): Lamp 1 cumulative operating time
2nd digit: 0 = Lamp 1 off, 1 = Lamp 1 on
3rd digits (1--5 digits): Lamp 2 cumulative operating time
4th digit: 0 = Lamp 2 off, 1 = Lamp 2 on
5th digits (1--5 digits): Lamp 3 cumulative operating time
6th digit: 0 = Lamp 3 off, 1 = Lamp 1 on
7th digits (1--5 digits): Lamp 4 cumulative operating time
8th digit: 0 = Lamp 4 off, 1 = Lamp 2 on
INST ?
Input selection list query
The following are returned as parameters.
“11 12 21 22 31” (If any of the ET-MD77DV, ET-MD77SD1, ET-MD77SD3 or
ET-MD100SD4 are installed, “11 12 21 22 31 32” is returned.)
NAME ?
Projector name query
The name set for “HOST NAME” in “NETWORK” is returned.
INF1 ?
Manufacturer name query
“Panasonic” is returned.
INF2 ?
Model name query
“D12000” or “DZ12000” is returned.
INFO ?
Other information query
Information such as version number is returned.
CLSS ?
Class information query
“1” is returned.
PJLink™ security authorization
When using PJLink™ with security authorization, either of the password set for administrator privileges and
the password set for user privileges with Web browser control can be used as the password for PJLink™.
When using PJLink™ without security authorization, set use without the password for administrator privileges
and the password for user privileges of Web browser control.
PJLink™ is a pending trademark in Japan, the United States, and other countries and regions.
•
For specifications regarding PJLink™, refer to the Japan Business Machine and Information System
Industries Association website.
URL: http://pjlink.jbmia.or.jp/