TIMER TABLE
Test Mode
Name
Time
(When test point
Remarks
Short-circuited)
Real Timer
1 hr.
1 min.
10 min.
10 sec.
1 min.
1 sec.
Time Delay Safety Control
2 min. 58 sec.
0 sec.
Forced Operation
60 sec.
0 sec.
Time Save Control
7 min.
4.2 sec.
Anti-Freezing
4 min.
0 sec.
Auto Mode Judgement
25 sec.
0 sec.
Soft Dry
OFF
6 min.
36 sec.
ON
10 min.
60 sec.
Soft Dry: 10 min. operation
Deodorizing Control
Cooling
40 sec.
4 sec.
70 sec.
7 sec.
20 sec.
2 sec.
180 sec.
18 sec.
Soft Dry
40 sec.
4 sec.
360 sec.
36 sec.
Comp. Reverse Rotation Detection
5 min.
30 sec.
Comp. ON 5 min. and above
2 min.
0 sec.
Comp./ Fan Motor Delay Timer
1.6 sec.
0 sec.
Powerful Mode Operation
15 min.
15 sec.
Random Auto Restart Control
0 ~ 62 sec.
0 ~ 6.2 sec.
TRS Recovery Detection
12 min.
72 sec.
6 min.
36 sec.
3 min.
18 sec.
1 min.
6 sec.
Time Save Control (Heating)
30 min.
3 sec.
4 Way Valve Control (Delay)
5 min.
30 sec.
Deice Operation Occurs
60 min.
6 sec.
60 min. after previous deice
4 min.
24 sec.
Continuously 4 min. Comp. ON
50 sec.
0 sec.
TRS ON continuously for 50 sec. check
Overload Deice Timer
1 min.
6 sec.
Comp. ON continuously for 1 min. check
Deice End
12 min.
72 sec.
Max. Operation time
30 sec.
3 sec.
30 sec. Comp. OFF after deice
10 sec.
1 sec.
4-Way Valve ON 10 sec. later after deice
Deice Operation (Extend)
60 sec.
0 sec.
120 sec.
0 sec.
180 sec.
0 sec.
Hotstart Finish
30 sec.
0 sec.
Ion OFF Timer
10 min.
10 sec.
84
CS-W7CKP CU-W7CKP5 / CS-W9CKP CU-W9CKP5 / CS-W12CKP CU-W12CKP5