1.
Vertical Airflow Direction
•
The louver swings up and down as shown above.
•
The louver does not swing when the Indoor Fan stops
during operation at the upper limit.
Heating Mode
•
When the intake air temp. reaches 38°C, the louver is
changed from upper to lower limit. When the intake air
temp falls to 35°C, the louver is changed from lower to
upper limit.
2.
Horizontal Airflow Direction
•
The louver can be selected between 14° - 36° (as
shown above) when pressing Manual Airflow Direction
Selection Button.
•
The louver can be selected between 0° - 61° (as shown
above)
when
pressing
Manual
Airflow
Direction
Selection Button.
8.9. Airflow Direction Control
Cooling, Ion and Soft Dry Mode
•
The left and right airflow direction louvers can be adjusted manually.
32
CS-W7CKP CU-W7CKP5 / CS-W9CKP CU-W9CKP5 / CS-W12CKP CU-W12CKP5