50
10. Do not install the indoor unit at a laundry. Electric shocks may result.
NOTE
• Study throughly the following installation locations.
1. In places such as restaurants and kitchens, considerable amount of oil steam and flour adhere to the fan, and the fin of the
heat exchanger may result in heat exchange reduction, spraying or dispersing of water drops, etc.
In these cases, take the following actions:
• Make sure the ventilation fan for smoke-collection hood on a cooking table has sufficient capacity so that it draws oily steam
which should not flow into the suction of the air conditioner.
• Make enough distance from cooking room to install the air conditioner in such place where it may not suck in oily steam.
2. Avoid installing the air conditioner in such circumstances where cutting oil mist or iron powder exist especially in factories, etc.
3. Avoid places where inflammable gas can be generated, flows-in, contaminated, or leak.
4. Avoid places where sulphurous acid gas or corrosive gas can be generated.
5. Avoid places near high frequency generators.
10.4.3.
Installation of indoor unit
The paper template for installation may expand or shrink according to temperature and humidity. Check the dimensions before using it.
CEILING OPENING DIMENSIONS AND HANGING BOLT LOCATION
Caution
During the installation, care must be taken not to damage the electric wires.
Summary of Contents for CS-F24DTE5
Page 18: ...18 4 Dimensions 4 1 CS F24DTE5 CS F28DTE5 ...
Page 19: ...19 4 2 CS F34DTE5 CS F43DTE5 CS F50DTE5 ...
Page 20: ...20 4 3 CU J24DBE5 CU J24DBE8 CU J28DBE5 CU J28DBE8 ...
Page 21: ...21 4 4 CU J34DBE5 CU J34DBE8 CU J43DBE8 CU J50DBE8 ...
Page 23: ...23 5 2 CS F34DTE5 CU J34DBE5 CU J34DBE8 CS F43DTE5 CU J43DBE8 CS F50DTE5 CU J50DBE8 ...
Page 25: ...25 6 3 CU J34DBE5 6 4 CU J24DBE8 CU J28DBE8 6 5 CU J34DBE8 CU J43DBE8 CU J50DBE8 ...
Page 26: ...26 7 Wiring Diagram 7 1 CS F24DTE5 CS F28DTE5 CS F34DTE5 CS F43DTE5 CS F50DTE5 ...
Page 27: ...27 7 2 CU J24DBE5 CU J28DBE5 ...
Page 28: ...28 7 3 CU J34DBE5 ...
Page 29: ...29 7 4 CU J24DBE8 CU J28DBE8 ...
Page 30: ...30 7 5 CU J34DBE8 CU J43DBE8 CU J50DBE8 ...
Page 32: ...32 8 2 Remote Control Display ...
Page 33: ...33 8 3 Remote Control Panel ...
Page 116: ...116 13 4 Sound data ...
Page 117: ...117 ...
Page 118: ...118 ...
Page 119: ...119 ...
Page 120: ...120 ...
Page 121: ...121 13 5 Sound measuring point 13 5 1 Indoor Unit 13 5 2 Outdoor Unit ...
Page 127: ...127 14 Exploded View Indoor Unit 14 1 CS F24DTE5 CS F28DTE5 ...
Page 128: ...128 14 2 CS F24DTE5 CS F28DTE5 ...
Page 129: ...129 14 3 CS F24DTE5 CS F28DTE5 ...
Page 132: ...132 16 Exploded View Indoor Unit 16 1 CS F34DTE5 CS F43DTE5 CS F50DTE5 ...
Page 133: ...133 16 2 CS F34DTE5 CS F43DTE5 CS F50DTE5 ...
Page 134: ...134 16 3 CS F34DTE5 CS F43DTE5 CS F50DTE5 ...
Page 137: ...137 18 Exploded View Outdoor Unit 18 1 CU J24DBE5 CU J24DBE8 CU J28DBE5 CU J28DBE8 ...
Page 138: ...138 18 2 CU J24DBE5 CU J24DBE8 CU J28DBE5 CU J28DBE8 ...
Page 140: ...140 20 Exploded View Outdoor Unit 20 1 CU J34DBE5 CU J34DBE8 CU J43DBE8 CU J50DBE8 ...
Page 141: ...141 20 2 CU J34DBE5 CU J34DBE8 CU J43DBE8 CU J50DBE8 ...
Page 142: ...142 20 3 CU J34DBE5 CU J34DBE8 CU J43DBE8 CU J50DBE8 ...
Page 144: ...144 22 Print Pattern 22 1 Indoor Unit Printed Main ...