10.4. Indoor unit installation
• Precautions shown here are differentiated between
Warnings and
Cautions. Those that have much chance for leading to
significant result such as fatality or serious injury if wrong installation would have been carried out are listed compiling them
especially into the column of
Warnings.
•
• However, even in the case of items which are listed in the column of
Cautions, such items also have a chance for leading to
significant result depending on the situations.
• In either case, important descriptions regarding the safety are listed, then observe them without fail.
• As to indications with illustration
• After installation work has been completed, do not only make sure that the unit is free from any abnormal condition through the
execution of trial run but also explain how to use and how to perform maintenance of this unit to the customer according to the
instruction manual.
In addition, request the customer to keep this manual for installation work together with instruction manual.
CEILING TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS
Precautions in terms of safety
Carry out installation work with reliability after throughout reading of this “Precautions in terms of safety”.
This mark means “Caution” or “Warning”.
This mark means “Earth”.
Warnings
The appliance must be installed by technician, who takes into
account the requirements given by ISO5149 or eventual
equivalent requirements.
If installing inside a small room, measures should be taken to
prevent refrigerant levels from building up to critical concentrations
in the event of a refrigerant leak occurring. Please discuss with the
place of purchase for advice on what measures may be necessary
to prevent critical concentrations being exceeded. If the refrigerant
leaks and reaches critical concentration levels, there is the danger
that death from suffocation may result.
As to installation, request the distributor or vendor to perform it.
Imperfection in installation caused by that having been carried out
by the customer himself may leads to water leakage, electric
shock, fire, etc.
Securely attach the protective covers for the outdoor unit
connection cables and power cord so that they do not lift up after
installation. If the covers are not properly attached and installed,
the terminal connections may overheat, and fire or electric shock
may result.
Carry out the installation work with reliability according to this
manual for installation work.
Imperfection in installation leads to water leakage, electric shock,
fire, etc.
Switch off all supplies before accessing any electrical part.
Carry out the installation work with reliability on the place that can
bear the weight of this unit sufficiently. Insufficient strength leads to
injury due to falling of the unit.
If refrigerant gas escapes during installation, ventilate the affected
area. If the refrigerant gas comes into contact with sparks or naked
flames, it will cause toxic gases to be generated.
Carry out predetermined installation work in preparation for strong
wind such as typhoon, earthquake. Imperfection in installation
work may lead to accidents arisen from overturn, etc.
Once installation work is completed, check that there are no
refrigerant gas in the room that can come into contact with sparks
or flames from a fan heater, stove or kitchen range, which will
cause toxic gases to be generated.
Summary of Contents for CS-F24DTE5
Page 18: ...18 4 Dimensions 4 1 CS F24DTE5 CS F28DTE5 ...
Page 19: ...19 4 2 CS F34DTE5 CS F43DTE5 CS F50DTE5 ...
Page 20: ...20 4 3 CU J24DBE5 CU J24DBE8 CU J28DBE5 CU J28DBE8 ...
Page 21: ...21 4 4 CU J34DBE5 CU J34DBE8 CU J43DBE8 CU J50DBE8 ...
Page 23: ...23 5 2 CS F34DTE5 CU J34DBE5 CU J34DBE8 CS F43DTE5 CU J43DBE8 CS F50DTE5 CU J50DBE8 ...
Page 25: ...25 6 3 CU J34DBE5 6 4 CU J24DBE8 CU J28DBE8 6 5 CU J34DBE8 CU J43DBE8 CU J50DBE8 ...
Page 26: ...26 7 Wiring Diagram 7 1 CS F24DTE5 CS F28DTE5 CS F34DTE5 CS F43DTE5 CS F50DTE5 ...
Page 27: ...27 7 2 CU J24DBE5 CU J28DBE5 ...
Page 28: ...28 7 3 CU J34DBE5 ...
Page 29: ...29 7 4 CU J24DBE8 CU J28DBE8 ...
Page 30: ...30 7 5 CU J34DBE8 CU J43DBE8 CU J50DBE8 ...
Page 32: ...32 8 2 Remote Control Display ...
Page 33: ...33 8 3 Remote Control Panel ...
Page 116: ...116 13 4 Sound data ...
Page 117: ...117 ...
Page 118: ...118 ...
Page 119: ...119 ...
Page 120: ...120 ...
Page 121: ...121 13 5 Sound measuring point 13 5 1 Indoor Unit 13 5 2 Outdoor Unit ...
Page 127: ...127 14 Exploded View Indoor Unit 14 1 CS F24DTE5 CS F28DTE5 ...
Page 128: ...128 14 2 CS F24DTE5 CS F28DTE5 ...
Page 129: ...129 14 3 CS F24DTE5 CS F28DTE5 ...
Page 132: ...132 16 Exploded View Indoor Unit 16 1 CS F34DTE5 CS F43DTE5 CS F50DTE5 ...
Page 133: ...133 16 2 CS F34DTE5 CS F43DTE5 CS F50DTE5 ...
Page 134: ...134 16 3 CS F34DTE5 CS F43DTE5 CS F50DTE5 ...
Page 137: ...137 18 Exploded View Outdoor Unit 18 1 CU J24DBE5 CU J24DBE8 CU J28DBE5 CU J28DBE8 ...
Page 138: ...138 18 2 CU J24DBE5 CU J24DBE8 CU J28DBE5 CU J28DBE8 ...
Page 140: ...140 20 Exploded View Outdoor Unit 20 1 CU J34DBE5 CU J34DBE8 CU J43DBE8 CU J50DBE8 ...
Page 141: ...141 20 2 CU J34DBE5 CU J34DBE8 CU J43DBE8 CU J50DBE8 ...
Page 142: ...142 20 3 CU J34DBE5 CU J34DBE8 CU J43DBE8 CU J50DBE8 ...
Page 144: ...144 22 Print Pattern 22 1 Indoor Unit Printed Main ...