(Remote Controller address setting)
(Refer to the Installation Manual which is provided with the remote controller for details.)
•
Two remote controllers (including the wireless remote controller) can be connected. However, remote control thermistor setting is not
possible.
•
As for [master/slave] setting of remote controller, the automatic setting and manual setting are possible. Since manual setting is priority.
•
Two remote controllers, which both are wireless, cannot be connected.
10.3.9. As for timer output
•
Connect the timer cord to connector (CN-TIMER) on print circuit board.
10.3.10. Precautions in test run
•
The initial power supply must provide at least 90% of the rated voltage. Otherwise, the air conditioner may not operate.
•
Test operation can be carried out using the remote control unit or at the outdoor unit. (If carrying out test operation at the
outdoor unit, refer to “TEST OPERATION” in the outdoor unit installation manual.)
•
If using the remote control unit to carry out test operation, follow the procedure given below.
•
First, press the OFF/ON (
) button.
•
Then press the TEST RUN button within 1 minute of pressing the OFF/ON (
) button.
•
Next, select the operation modes.
•
The temperature of the indoor unit pipes will be shown on the temperature setting display. (At the start of the test
operation, it may take up to 1 minute for air conditioner number, switching time and other displays to appear.)
•
After operation modes have been selected, stop the compressor for a moment.
•
Press the OFF/ON (
) button of the TEST RUN button once more to cancel test operation mode.
NOTE 1
These units are equipped with connection error prevention circuits. If the units do not operate, it is possible that the connection
error prevention circuits have been operated. In such cases, check that the Indoor/outdoor unit connection wire (connected to
terminals
,
and
) is connected correctly. If they are connected incorrectly, connect them correctly. Normal operation
should then commence.
NOTE 2
Do not short the remote control unit wires to each other. (The protection circuit will be activated and the units will not operate.)
Once the cause of the short is eliminated, normal operation will then be possible.
NOTE 3
When running the units in heating mode during test operation, be sure to run the units in cooling mode first before selecting
this mode. If heating mode is selected first, it may cause problems with operation of the compressor. (Heat pump model only.)
NOTE 4
Test operation should be carried out for a minimum of 5 minutes. (Test operation will be cancelled automatically after 30
minutes.)
NOTE 5
Test operation mode should always be cancelled once test operation itself has been completed.
43
Summary of Contents for CS-F14DD3E5
Page 8: ...4 DIMENSIONS 4 1 CS F14DD3E5 CS F18DD3E5 8 ...
Page 9: ...4 2 CU B14DBE5 CU B18DBE5 9 ...
Page 10: ...5 REFRIGERATION CYCLE 5 1 CS F14DD3E5 CU B14DBE5 CS F18DD3E5 CU B18DBE5 10 ...
Page 11: ...6 BLOCK DIAGRAM 6 1 CS F14DD3E5 CS F18DD3E5 6 2 CU B14DBE5 11 ...
Page 12: ...6 3 CU B18DBE5 12 ...
Page 13: ...7 WIRING DIAGRAM 7 1 CS F14DD3E5 CS F18DD3E5 13 ...
Page 14: ...7 2 CU B14DBE5 14 ...
Page 15: ...7 3 CU B18DBE5 15 ...
Page 17: ...8 2 Remote control display 17 ...
Page 18: ...8 3 Remote control panel 18 ...
Page 85: ...13 TECHNICAL DATA 13 1 Sound data 85 ...
Page 86: ...86 ...
Page 87: ...13 2 Sound measurement point 13 2 1 Indoor unit 13 2 2 Outdoor unit 87 ...
Page 89: ...HEATING 89 ...
Page 91: ...91 ...
Page 93: ...93 ...
Page 95: ...13 5 Fan performance 13 5 1 CS F14DD3E5 Fan performance test report Fan performance curve 95 ...
Page 96: ...13 5 2 CS F18DD3E5 Fan performance test report Fan performance curve 96 ...
Page 99: ...14 REPLACEMENT PARTS 14 1 Indoor unit CS F14DD3E5 CS F18DD3E5 99 ...
Page 101: ...14 2 Outdoor unit CU B14DBE5 CU B18DBE5 101 ...
Page 102: ...CU B14DBE5 CU B18DBE5 102 ...
Page 104: ...15 PRINT PATTERN 15 1 Indoor unit INDOOR UNIT PRINTED CIRCUIT BOARD MAIN 104 ...