11. Installation
Instruction
IMPORTANT (ONLY FOR E9SD3UAW AND E12SD3UAW)
This product has been designed and manufactured to meet ENERGY STAR
®
criteria for energy efficiency when
matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical to
achive rated capacity and efficiency. Installation of this product should follow the manufacturer’s refrigerant
charging and air flow instructions.
Failure to confirm proper charge and airflow may reduce energy
efficiency and shorten equipment life.
Attached Accessories
No.
Accessory part
Qty.
1
Remote control
1
2
Battery
2
3
Remote control holder
1
4
Remote control holder
fi xing screw
2
5
Remote control receiver
1
No.
Accessory part
Qty.
6
Receiver fi xing screw
(M4 x 39/64" (15.5 mm))
2
7
Clamper (band)
(for receiver cable fi xing)
1
8
Receiver cable
(6.56 ft (2 m))
1
9
Washer
(for suspension fi tting)
8
0
Flare insulator
(for gas pipe / liquid pipe
connection)
2
No.
Accessory part
Qty.
!
Clamper (band)
(for fl are & drain insulating
connection)
4
@
Drain hose
(for unit & PVC pipe
connection)
1
#
Hose band
(for drain hose connection)
1
$
Drain hose insulation
(for drain pipe connection)
2
%
Clamper (band)
(for power supply cord)
1
* Be sure to fi x the power supply cord
with clamper (band).
¥
Drain elbow
1
L=131
■
Required Materials
Read the catalog and other technical materials and prepare the required materials.
Applicable piping kit
Applicable piping kit
Piping size
Gas Liquid
CZ-3F5, 7BP
3/8" (9.52 mm)
1/4" (6.35 mm)
CZ-4F5, 7, 10BP
1/2" (12.7 mm)
1/4" (6.35 mm)
CZ-52F5, 7, 10BP
5/8" (15.88 mm)
1/4" (6.35 mm)
Pipe size reducer (CZ-MA1P) for outdoor Multi connection CS-E12SD3UAW, CS-E18SD3UAW