24
8.2 Outdoor
Unit
8.2.1
CU-E9SD3UA CU-E12SD3UA
t˚
t˚
t˚
M
M
FAN
MOTOR
GRN
GRN
1
P
N
U
V
W
Q1
4
7
BLK
BLK
L2
TO INDOOR UNIT
SINGLE PHASE
POWER SUPPLY
L1
YLW/GRN
1
(BLACK)
2
(WHITE)
3
(RED)
WHT
FG1 (GRN)
CN-DCFM
(WHT)
LJP101 (GRN)
FUSE103
T3.15A L250V
ELECTRONIC CONTROLLER
WHT
RED
DATA (RED)
TERMINAL BOARD
COMMUNICATION
CIRCUIT
NOISE FILTER
CIRCUIT
PFC
CIRCUIT
RECTIFICATION
CIRCUIT
RECTIFICATION
CIRCUIT
SWITCHING
POWER SUPPLY
CIRCUIT
GRY
GRY
ELECTRO-MAGNETIC
COIL (EXPANSION VALVE)
1
6
1
1
2
3
3
4
RAT2
(GRY)
RAT1
(GRY)
YLW
1
2
YLW
FUSE102
T3.15A L250V
CN-STM
(WHT)
CN-TH
(WHT)
CN-TANK
(WHT)
CN-HOT
(WHT)
(RED)
(BLU)
(YLW)
RED
COMPRESSOR
BLU
MS
3~
YLW
AIR TEMP. SENSOR
(THERMISTOR)
PIPING TEMP. SENSOR
(THERMISTOR)
COMPRESSOR TEMP. SENSOR
(THERMISTOR)
ELECTRO-MAGNETIC
COIL (4-WAY VALVE)
YELLOW (YEL)
BLUE (BLU)
RED (RED)
(TRADEMARK)
COMPRESSOR TERMINAL
THE PARENTHESIZED LETTERS IS
INDICATED ON TERMINAL COVER
REACTOR
AC-BLK
(BLK)
FUSE101
20A 250V
AC-WHT
(WHT)
REMARKS
BLK: BLACK
BLU: BLUE
WHT: WHITE
RED : RED
YLW : YELLOW
GRY : GRAY
GRN: GREEN
BRW: BROWN
ORG: ORANGE
YLW/GRN: YELLOW/GREEN
Resistance of Compressor Windings
MODEL CU-E9SD3UA/CU-E12SD3UA
CONNECTION 5RS102XHA21
U-V 1.741
Ω
U-W 1.765
Ω
V-W 1.711
Ω
Note: Resistance at 68°F of ambient temperature.