14.2. Indoor Fan Motor and Cross Flow Fan Removal Procedures
• Pull down the Discharge Grille Complete. (Fig. 5)
Fig. 5
• Remove the earth wire from the evaporator. (Fig. 6)
• Remove 2 screws on the right and 1 screw at the left side of
control board. (Fig. 6)
• Then pull out the control board from the unit. (Fig. 6)
Fig. 6
• Remove the cross flow fan bushing from the chassis. (Fig.
• Loosen the fan boss screw at the cross flow fan.
Fig. 7