13
8 Wiring Connection Diagram
8.1.
CS-C12EKF CU-C12EKF
Resistance of Outdoor Fan Motor Windings
Note: Resistance at 26
°
C of ambient temperature.
Resistance of Compressor Windings
Note: Resistance at 20
°
C of ambient temperature.
MODEL
CU-C12EKF
CONNECTION
CWA951120
BLUE-YELLOW
200.4
Ω
YELLOW-RED
252.5
Ω
MODEL
CU-C12EKF
CONNECTION
2KS210D3BA02
C - R
1.930
Ω
C - S
2.449
Ω