32
11.10. Quiet Operation
(For Cooling Operation or cooling region of Soft Dry Operation)
•
To provide quiet/cooling operation condition compare to normal operation.
• Once the Quiet Mode is set at the remote control, the Quiet Mode LED illuminated. The sound level will reduce around 2 dB(A)
for Lo fan speed or 3 dB(A) for Hi/Me fan speed against the present operation sound level.
• Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1hr 30 min (1hr QLo, 30 min QLo + 50
rpm). After that, it goes back to Lo cool (However Quiet LED remains on).
• Manual Airflow Direction:-
- RPM control during Lo cool
- RPM control during Hi & Me cool
• Auto Fan Speed:-
• Quiet operation stops when:-
- Quiet button is pressed again.
- Stopped by OFF/ON operation button.
- Timer OFF activates.
- Powerful button is pressed.
- Operation mode button is changed.
Summary of Contents for CS-C12EKF
Page 9: ...9 5 Dimensions 5 1 Indoor Unit Remote Control 5 1 1 CS C12EKF ...
Page 10: ...10 5 2 Outdoor Unit 5 2 1 CU C12EKF ...
Page 11: ...11 6 Refrigeration Cycle Diagram ...
Page 12: ...12 7 Block Diagram ...
Page 14: ...14 9 Printed Circuit Board 9 1 Indoor Unit TOP VIEW ...
Page 15: ...15 BOTTOM VIEW ...
Page 16: ...16 9 2 Indicator TOP VIEW BOTTOM VIEW ...
Page 42: ...42 15 Technical Data 15 1 Thermostat Characteristics Cooling Soft Dry ...
Page 43: ...43 15 2 Operation Characteristics 15 2 1 CS C12EKF CU C12EKF ...
Page 44: ...44 ...
Page 46: ...46 ...