24
11.2. Soft Dry Operation
• Soft Dry operation can be set using remote control.
• Soft Dry operation is applied to dehumidify and to perform a gentle cooling to the room.
• This operation starts when the intake air temperature sensor reaches the setting temperature on the remote control.
• When operation begins, Soft Dry will be switched “ON” for a maximum 10 minutes, then Soft Dry operation will be turned “OFF”
for a minimum 6 minutes. After that, the Soft Dry operation will be “ON” and “OFF” based on the setting temperature as shown in
below figure.
• However after 3 minutes of compressor off, during Soft Dry “OFF” (within 6 minutes Soft Dry restart control), the indoor unit will
start to operate at normal Cooling mode if the intake temperature is higher than Cooling “ON” point.
11.2.1.
Soft Dry Operation Time Diagram
Summary of Contents for CS-C12EKF
Page 9: ...9 5 Dimensions 5 1 Indoor Unit Remote Control 5 1 1 CS C12EKF ...
Page 10: ...10 5 2 Outdoor Unit 5 2 1 CU C12EKF ...
Page 11: ...11 6 Refrigeration Cycle Diagram ...
Page 12: ...12 7 Block Diagram ...
Page 14: ...14 9 Printed Circuit Board 9 1 Indoor Unit TOP VIEW ...
Page 15: ...15 BOTTOM VIEW ...
Page 16: ...16 9 2 Indicator TOP VIEW BOTTOM VIEW ...
Page 42: ...42 15 Technical Data 15 1 Thermostat Characteristics Cooling Soft Dry ...
Page 43: ...43 15 2 Operation Characteristics 15 2 1 CS C12EKF CU C12EKF ...
Page 44: ...44 ...
Page 46: ...46 ...