![Panasonic CS-A12KKD-2 Service Manual Download Page 6](http://html.mh-extra.com/html/panasonic/cs-a12kkd-2/cs-a12kkd-2_service-manual_256573006.webp)
6
2. Specification
Indoor CS-A9KKD-2
CS-A12KKD-2
Model
Outdoor CU-A9KKD-2
CU-A12KKD-2
Performance Test Condition
NEW JIS
NEW JIS
Phase, Hz
Single, 50
Single, 50
Power Supply
V
220 230 220 230
kW
2.43 2.43 3.22 3.23
BTU/h 8300
8300
11000
11030
Capacity
kJ/h
2090 2090 2770 2780
Running
Current
A
4.3 4.2 5.0 5.0
Input Power
W
930
950
1.08k
1.10k
W/W
2.61 2.56 2.98 2.94
EER
Btu/hW 8.92
8.74
10.19
10.03
Power
Factor
%
98 98 98 96
dB-A
36 / 26
36 / 26
39 / 29
39 / 29
Indoor Noise (H / L)
Power Level dB
-
-
-
-
dB-A
48 / -
49 / -
55 / -
55 / -
Cooling
Outdoor Noise (H / L)
Power Level dB
-
-
-
-
kW
2.64 2.66 3.81 3.83
BTU/h 9010
9080
13000
13080
Capacity
kcal/h
2270 2290 3280 3290
Running
Current
A
3.3 3.3 4.8 4.8
Input Power
W
710
740
1.03k
1.06k
W/W
3.72 3.59 3.70 3.61
COP
Btu/hW
12.69 12.27 12.62 12.34
Power
Factor
%
98 97 98 96
dB-A
38 / 28
38 / 28
40 / 29
40 / 29
Indoor Noise (H / L)
Power Level dB
-
-
-
-
dB-A
48 / -
49 / -
56 / -
56 / -
Heating
Outdoor Noise (H / L)
Power Level dB
-
-
-
-
Max Current (A) / Max Input Power (W)
5.1 / 1.13k
6.0 / 1.35k
Starting Current (A)
18.0
20.0
Type
Hermetic Motor
Hermetic Motor
Motor Type
Induction (2 poles)
Induction (2 poles)
Compressor
Output Power
W
750
950
Type
Cross-Flow Fan
Cross-Flow Fan
Material
ASG20K1
ASG20K1
Motor Type
Induction (4 poles)
Induction (4 poles)
Input Power
W
32.6 - 33.6
41.4 - 42.9
Output Power
W
24
24
QLo rpm
-
-
Lo rpm
Cooling: 730 - 730
Heating: 780 - 780
Cooling: 800 - 800
Heating: 840 - 840
Me rpm
Cooling: 870 - 870
Heating: 870 - 870
Cooling: 950 - 950
Heating: 950 - 950
Hi rpm
Cooling: 1040 - 1040
Heating: 1080 - 1080
Cooling: 1100 - 1100
Heating: 1120 - 1120
Indoor Fan
Speed
SHi rpm
Cooling: 1080 - 1080
Cooling: 1120 - 1120
Summary of Contents for CS-A12KKD-2
Page 3: ...3 18 Exploded View and Replacement Parts List 125 18 1 Indoor Unit 125 18 2 Outdoor Unit 131 ...
Page 16: ...16 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 17: ...17 5 Dimensions 5 1 Indoor Unit 5 1 1 CS A9KKD 2 CS A12KKD 2 ...
Page 18: ...18 5 1 2 CS A18KKD 2 CS A24KKD 2 CS A28KKD 2 ...
Page 19: ...19 5 2 Outdoor Unit 5 2 1 CU A9KKD 2 5 2 2 CU A12KKD 2 ...
Page 20: ...20 5 2 3 CU A18KKD 2 CU A24KKD 2 CU A28KKD 2 ...
Page 21: ...21 6 Refrigeration Cycle Diagram 6 1 CS A9KKD 2 CU A9KKD 2 CS A12KKD 2 CU A12KKD 2 ...
Page 22: ...22 6 2 CS A18KKD 2 CU A18KKD 2 CS A24KKD 2 CU A24KKD 2 CS A28KKD 2 CU A28KKD 2 ...
Page 23: ...23 7 Block Diagram 7 1 CS A9KKD 2 CU A9KKD 2 ...
Page 24: ...24 7 2 CS A12KKD 2 CU A12KKD 2 ...
Page 25: ...25 7 3 CS A18KKD 2 CU A18KKD 2 CS A24KKD 2 CU A24KKD 2 ...
Page 26: ...26 7 4 CS A28KKD 2 CU A28KKD 2 ...
Page 31: ...31 9 Electronic Circuit Diagram 9 1 CS A9KKD 2 CU A9KKD 2 ...
Page 32: ...32 9 2 CS A12KKD 2 CU A12KKD 2 ...
Page 33: ...33 9 3 CS A18KKD 2 CU A18KKD 2 CS A24KKD 2 CU A24KKD 2 ...
Page 34: ...34 9 4 CS A28KKD 2 CU A28KKD 2 ...
Page 36: ...36 10 1 1 2 CS A28KKD 2 ...
Page 39: ...39 10 1 7 Eco Patrol Printed Circuit Board ...
Page 86: ...86 Normal Deice Time Diagram Overload Deice Time Diagram ...
Page 91: ...91 a Normal Deice Time Diagram b Overload Deice Time Diagram ...
Page 97: ...97 Figure 3 Figure 4 Figure 5 16 1 1 3 To remove discharge grille Figure 6 ...
Page 99: ...99 Figure 10 Figure 11 ...
Page 101: ...101 16 2 1 3 To remove power electronic controller Figure 14 Figure 15 Figure 16 Figure 17 ...
Page 103: ...103 Figure 21 Figure 22 Figure 23 ...
Page 104: ...104 17 Technical Data 17 1 Thermostat Characteristics ...