11.3.4
Connect the cable to the Outdoor Unit
a) INDOOR POWER SUPPLY MODEL (1.0~2.5HP)
1
Remove the control board cover from the
unit by loosening the screw.
2
Connecting cable
between indoor unit and
outdoor unit shall be approved
polychloroprene sheathed 5 x 1.5mm
2
(1.0~1.5HP) or 5 x 2.5mm
2
(2.0~2.5HP)
flexible cord, type designation 245 IEC 57 or
heavier cord.
3
Secure the cable onto the control board with
the holder.
4
Attach the control board cover back to the
original position with the screw.
5 For wire stripping and connection requirement,
refer to instruction
g
of the indoor unit.
This equipment must be properly earthed.
•
Earth wire shall be Yellow/Green (Y/G) in colour and longer than the other AC wires for safety reason.
b) OUTDOOR POWER SUPPLY MODEL (3.0HP)
1
Remove the control board cover from the
unit by loosening the screw.
2
Cable connection to the power supply through
Isolating Devices (Disconnecting means).
•
Connecting approved type
polychloroprene sheathed
power supply
cord
3 x 4.0mm
2
(3.0HP), type
designation 245 IEC 57 or heavier cord to
the terminal board, and connect the other
end of the cord to Isolating Devices
(Disconnecting means).
3
Connecting cable
between indoor unit and
outdoor unit shall be approved
polychloroprene sheathed 6 x 1.5mm
2
flexible
cord, type designation 245 IEC 57 or heavier
cord.
4
Connect the power supply cord and
connecting between indoor unit and outdoor
unit according to the diagram below.
5
Secure the power supply cord and connecting
cable onto the control board with the holder.
6
Attach the control board cover back to the
original position with the screw.
7 For wire stripping and connection requirement,
refer to instruction
g
of the indoor unit.
This equipment must be properly earthed.
•
Note: Isolating Devices (Disconnecting means) should have minimum 3.0 mm contact gap.
•
Earth wire shall be Yellow/Green (Y/G) in colour and longer than the other AC wires for safety reason.
Summary of Contents for CS-A12KKD-2
Page 3: ...3 18 Exploded View and Replacement Parts List 125 18 1 Indoor Unit 125 18 2 Outdoor Unit 131 ...
Page 16: ...16 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 17: ...17 5 Dimensions 5 1 Indoor Unit 5 1 1 CS A9KKD 2 CS A12KKD 2 ...
Page 18: ...18 5 1 2 CS A18KKD 2 CS A24KKD 2 CS A28KKD 2 ...
Page 19: ...19 5 2 Outdoor Unit 5 2 1 CU A9KKD 2 5 2 2 CU A12KKD 2 ...
Page 20: ...20 5 2 3 CU A18KKD 2 CU A24KKD 2 CU A28KKD 2 ...
Page 21: ...21 6 Refrigeration Cycle Diagram 6 1 CS A9KKD 2 CU A9KKD 2 CS A12KKD 2 CU A12KKD 2 ...
Page 22: ...22 6 2 CS A18KKD 2 CU A18KKD 2 CS A24KKD 2 CU A24KKD 2 CS A28KKD 2 CU A28KKD 2 ...
Page 23: ...23 7 Block Diagram 7 1 CS A9KKD 2 CU A9KKD 2 ...
Page 24: ...24 7 2 CS A12KKD 2 CU A12KKD 2 ...
Page 25: ...25 7 3 CS A18KKD 2 CU A18KKD 2 CS A24KKD 2 CU A24KKD 2 ...
Page 26: ...26 7 4 CS A28KKD 2 CU A28KKD 2 ...
Page 31: ...31 9 Electronic Circuit Diagram 9 1 CS A9KKD 2 CU A9KKD 2 ...
Page 32: ...32 9 2 CS A12KKD 2 CU A12KKD 2 ...
Page 33: ...33 9 3 CS A18KKD 2 CU A18KKD 2 CS A24KKD 2 CU A24KKD 2 ...
Page 34: ...34 9 4 CS A28KKD 2 CU A28KKD 2 ...
Page 36: ...36 10 1 1 2 CS A28KKD 2 ...
Page 39: ...39 10 1 7 Eco Patrol Printed Circuit Board ...
Page 86: ...86 Normal Deice Time Diagram Overload Deice Time Diagram ...
Page 91: ...91 a Normal Deice Time Diagram b Overload Deice Time Diagram ...
Page 97: ...97 Figure 3 Figure 4 Figure 5 16 1 1 3 To remove discharge grille Figure 6 ...
Page 99: ...99 Figure 10 Figure 11 ...
Page 101: ...101 16 2 1 3 To remove power electronic controller Figure 14 Figure 15 Figure 16 Figure 17 ...
Page 103: ...103 Figure 21 Figure 22 Figure 23 ...
Page 104: ...104 17 Technical Data 17 1 Thermostat Characteristics ...