3. Basic operations
3-6-5. DSK adjustments
The DSK definition can be adjusted.
Press the [DSK1] button (or [DSK2] button) to light its indicator and display the DSK1 menu (or DSK2
menu).
Refer to “2-1-5. LCD menu area”.
Turn [F1] to display the Adjust sub menu.
<Menu
display>
DSK1 2|Clip |Gain |Density|Invert
Adjust | 0.0| 100.0| 100.0| Off
Turn [F2], [F3] and [F4] to adjust the DSK (downstream key) definition.
Turn [F5] to set key invert.
If On is set, the key signals generated internally are inverted.
Operation
Parameter
Description of setting
Setting range
F2
Clip
Reference level for generating key signals
0.0 to 108.0
F3
Gain
Key amplitude
0.0 to 200.0
F4
Density
Key density
0.0 to 100.0
F5
Invert
Key signal inversion
On, Off