126
4. Input/output signal settings
4-8-3. Setting the tally displays
Set the tally displays to be superimposed onto the split frame of the multi view display.
The red tally indicates material consisting of program outputs.
The green tally indicates material selected by the preset bus.
On the MV1 Frame or MV2 Frame sub menu, turn [F5] to set the tally displays using the Tally item.
<Menu
display>
MV 2|Frame | Char|Label |Tally
MV1Frame| LUM75%| LUM75%| On|Red+GRN
LUM 0%
LUM25%
LUM50%
LUM100%
Off
LUM 0%
LUM25%
LUM50%
LUM100%
Off
Off Red
Off
MV 4|Frame | Char|Label |Tally
MV2Frame| LUM75%| LUM75%| On|Red+GRN
LUM 0%
LUM25%
LUM50%
LUM100%
Off
LUM 0%
LUM25%
LUM50%
LUM100%
Off
Off Red
Off
Red+GRN:
Both the red tally and green tally are displayed.
Red:
Only the red tally is displayed.
Off:
No tally displays are shown.
The red tally is not displayed during FTB operation while the program images have been completely faded
out to a black screen. At this time, the green tally is displayed for images consisting of program images.
The red tally and green tally signals are output from the tally output connector on the rear panel.
Refer to “5-7-3. Setting the GPI”.