152
Stop condition
1) In case of “Sound” is set for “Quiet priority” on the remote control
If any of below condition is achieved
OFF/ON button is pressed.
Quiet mode is OFF by remote control.
Quiet mode is request OFF by weekly timer.
2) In case of “Capacity” is set for “Quiet priority” on the remote control
If any of below condition is achieved
OFF/ON button is pressed.
Quiet mode is OFF by remote control.
Quiet mode is request OFF by weekly timer.
During heating : Water outlet temperature ≤ Target Water Tempe [ -5°C ] for continuously
[ 30 ] minutes.
During Cooling : Water outlet temperature ≥ Target Water Tempe [ 5°C ] for continuously
[ 30 ] minutes.
During tank heat up : Tank temperature ≤ Tank set tempe [ -5°C ] for continuously [ 30 ] minutes.
14.13 Sterilization Mode
Purpose:
o
To sterilize water tank by setting the required boiling temperature.
Remote control setting
o
Days for sterilization function to start can be select.
o
Time of selected day to start sterilization function.
o
Boiling temperature (Internal heater is 55°C ~ 65°C)
o
Maximum operation time is 5 minutes to 1 hour.
Start condition
o
Tank connection set to “YES” by remote control
o
Sterilization function selects “YES”.
o
Sterilization signal received from remote controller by timer.
o
Tank mode request ON.
Stop condition
o
When boiling timer is completed. Boiling timer (Remote control set maximum operation time) start counting
once tank achieve boiling set temperature
OR
o
After 8 hours of operation since sterilization start.
o
Tank mode request OFF.
Control content:
o
During sterilization function activation time, target tank set temperature will internally change to boiling set
temperature.
o
During sterilization activates, heat pump and heater (external or internal) will operate as normal tank mode to
achieve the boiling set temperature.
o
Sterilization operation will end when stop condition is fulfill.
o
After sterilization is complete, tank set temperature will resume to normal operation.
* Tank temperature may not achieve boiling set temperature if tank heater is select OFF
OR
external compressor
switch.