98
Setup Menu: Menu List
_ is the factory default setting.
EXT DC IN
Item
Settings and brief function description
FREQ indications
EXT DC IN
SELECT
Sets the remaining level detection type for when an external DC power supply or battery is
connected to the DC IN connector. Set NEAR END and END of TYPE A and TYPE B to match
the battery that is to be used.
DC PWR SUPPLY
TYPE A
TYPE B
TYPE A NEAR END
Sets the voltage (in 0.1 V steps) at which to display warning information when the voltage
drops for the battery to be used as “TYPE-A” selected in the “EXT DC IN SELECT” menu
item.
10.6 V
to
12.9 V
to
15.0 V
Note:
A voltage that will be lower than END cannot be set.
TYPE A END
Sets the voltage (in 0.1 V steps) at which to automatically turn off the power of the unit when
the voltage drops for the battery to be used as “TYPE-A” selected in the “EXT DC IN SE-
LECT” menu item.
10.6 V
to
12.4 V
to
15.0 V
Note:
A voltage that will be higher than NEAR cannot be set.
TYPE B NEAR END
Sets the voltage (in 0.1 V steps) at which to display warning information when the voltage
drops for the battery to be used as “TYPE-B” selected in the “EXT DC IN SELECT” menu
item.
10.6 V
to
12.9 V
to
15.0 V
Note:
A voltage that will be lower than END cannot be set.
TYPE B END
Sets the voltage (in 0.1 V steps) at which to automatically turn off the power of the unit when
the voltage drops for the battery to be used as “TYPE-B” selected in the “EXT DC IN SE-
LECT” menu item.
10.6 V
to
12.4 V
to
15.0 V
Note:
A voltage that will be higher than NEAR cannot be set.
59.94Hz
50Hz
59.94Hz
50Hz
59.94Hz
50Hz
59.94Hz
50Hz
59.94Hz
50Hz