15.1 Pulse Output Unit Operation If an Error Occurs
15.1.1 If the Pulse Output Unit ERROR LED Lights
■
When starting (stopped)
● If a limit error occurs when the pulse output unit is started (stopped), various operations will
not begin.
● This applies to E-point control, P-point control, home return, JOG operation, JOG positioning
operation and pulser input operation, none of which will be initiated.
■
During operation
● If a limit error occurs, the pulse output unit interrupts any operation currently in progress, and
starts the stop operation.
● When a limit error occurs, operation cannot be restarted until the error is cleared by executing
the PG_ClearError function block.
● Operation continues on other axes where the error has not occurred.
15.1.2 If the Controller ERROR LED Lights
The pulse output unit interrupts any operation currently in progress, and enters the
"deceleration stop" status.
15.1 Pulse Output Unit Operation If an Error Occurs
15-2
WUME-GM1PG-01
Summary of Contents for AGM1PG04L
Page 2: ... MEMO 2 WUME GM1PG 01 ...
Page 14: ... MEMO 1 4 WUME GM1PG 01 ...
Page 22: ... MEMO 2 8 WUME GM1PG 01 ...
Page 42: ... MEMO 3 20 WUME GM1PG 01 ...
Page 52: ...4 5 Increment and Absolute 4 10 WUME GM1PG 01 ...
Page 70: ...AccDec 10000 END_CASE 6 1 Sample Program 6 6 WUME GM1PG 01 ...
Page 82: ... MEMO 7 10 WUME GM1PG 01 ...
Page 90: ... MEMO 8 8 WUME GM1PG 01 ...
Page 94: ...AccDec 10000 END_CASE 9 1 Sample Program 9 4 WUME GM1PG 01 ...
Page 116: ... MEMO 10 20 WUME GM1PG 01 ...
Page 124: ... MEMO 11 8 WUME GM1PG 01 ...
Page 142: ... MEMO 14 4 WUME GM1PG 01 ...
Page 158: ...16 3 Dimensions 16 3 1 Pulse Output Unit Unit mm 16 3 Dimensions 16 8 WUME GM1PG 01 ...
Page 162: ... MEMO App 4 WUME GM1PG 01 ...
Page 164: ... MEMO WUME GM1PG 01 ...
Page 165: ... MEMO WUME GM1PG 01 ...
Page 166: ...Panasonic Corporation 2021 August 2021 WUME GM1PG 01 ...