5.4 Confirming while the Power is ON
5.4.1 Items to Check when the Power is ON
■
System configuration example
When the power to the system incorporating the pulse output unit is turned ON, checking
should be carried out in the four general stages described below.
1. Checking the installation of the external safety circuit
2. Checking the installation of the safety circuit based on the pulse output unit
3. Checking the motor’s rotation direction, moving direction, and moving distance.
4. Checking the near home input and home input
5.4.2 Checking the External Safety Circuit
Check the safety circuit recommended by the motor manufacturer to confirm the power supply
cutoff of the motor driver and other functions by turning ON the CW / CCW driving inhibition
switch of an external circuit.
5.4.3 Checking the Safety Circuit based on Pulse Output Unit
1.
Perform a forced operation on the over limit switch for the safety circuit of the positioning
unit
1-1
Check to see if the over limit input is being properly taken into the pulse output unit.
5.4 Confirming while the Power is ON
5-6
WUME-GM1PG-01
Summary of Contents for AGM1PG04L
Page 2: ... MEMO 2 WUME GM1PG 01 ...
Page 14: ... MEMO 1 4 WUME GM1PG 01 ...
Page 22: ... MEMO 2 8 WUME GM1PG 01 ...
Page 42: ... MEMO 3 20 WUME GM1PG 01 ...
Page 52: ...4 5 Increment and Absolute 4 10 WUME GM1PG 01 ...
Page 70: ...AccDec 10000 END_CASE 6 1 Sample Program 6 6 WUME GM1PG 01 ...
Page 82: ... MEMO 7 10 WUME GM1PG 01 ...
Page 90: ... MEMO 8 8 WUME GM1PG 01 ...
Page 94: ...AccDec 10000 END_CASE 9 1 Sample Program 9 4 WUME GM1PG 01 ...
Page 116: ... MEMO 10 20 WUME GM1PG 01 ...
Page 124: ... MEMO 11 8 WUME GM1PG 01 ...
Page 142: ... MEMO 14 4 WUME GM1PG 01 ...
Page 158: ...16 3 Dimensions 16 3 1 Pulse Output Unit Unit mm 16 3 Dimensions 16 8 WUME GM1PG 01 ...
Page 162: ... MEMO App 4 WUME GM1PG 01 ...
Page 164: ... MEMO WUME GM1PG 01 ...
Page 165: ... MEMO WUME GM1PG 01 ...
Page 166: ...Panasonic Corporation 2021 August 2021 WUME GM1PG 01 ...