COMMISSIONING
EXTRA WIDE BACK COVER KIT INSTALLATION
Warnings:
Warning: Before installing the back cover kit, ensure the heaters exhaust tube and air intake hose are firmly
connected.
Warning: Ensure that nothing (including air intake hose) is in contact with metallic parts of the heaters exhaust
tube. Reposition telescopic exhaust tube insulating sock if required.
Notes:
If installing a Sideways Flue System, knock out the large hole on the relevant side cover, disconnect coaxial flue pipe
from manifold assembly, insert flue pipe through cover and reconnect and silicone seal flue pipe to manifold
assembly when performing step 2 or 4 of the following procedure.
Procedure:
1.
Remove two lower brackets on rear of heater
and replace with brackets supplied in Extra
Wide Back Cover Kit (fix new brackets using
existing heater bracket screws).
2.
Align LH side cover screw holes over holes in
heater lower bracket and insert cover location
tab into heater side slot.
3.
Fasten LH side cover to lower bracket with two
screws.
4.
Align RH side cover screw holes over holes in
heater lower bracket and insert cover location
tab into heater side slot.
5.
Fasten RH side cover to lower bracket with two screws.
6.
Align top cover over top of LH & RH side covers and the two wall brackets.
7.
Fasten top cover to side covers with four screws (two on each side).
24