FLUEING
AS/NZS 5601.1 Figure 6.2
flue terminal location guide.
All dimensions are measured to the nearest part of the flue terminal.
Ref
Item
Minimum Clearances (mm)
Natural Draught Fan Assisted
a
Below eaves, balconies and other projections:
•
Appliances up to 50 MJ/h input
300
200
•
Appliances over 50 MJ/h input
500
300
b
From the ground, above a balcony or other surface *
300
300
c
From a return wall or external corner * (refer to note 2)
500
300
d
From a gas meter (M)
1000
1000
e
From an electricity meter or fuse box (P) (refer to note 1)
500
500
f
From a drain pipe or soil pipe
150
75
g
Horizontally from any building structure * or obstruction facing a terminal
500
500
h
From any other flue terminal, cowl, or combustion air intake *
500
300
j
Horizontally from an openable window, door, non-mechanical air inlet or
any other opening into a building with the exception of sub-floor ventilation
(refer to note 2):
•
Appliances up to 150MJ/h input *
500
300
•
Appliances over 150MJ/h input up to 200 MJ/h input *
1500
300
•
Appliances over 200MJ/h input up to 250 MJ/h input *
1500
500
•
Appliances over 250 MJ/h input *
1500
1500
All fan assisted flue appliances, in the direction of discharge
-
1500
k
From a mechanical air inlet, including a spa blower (refer to note 2)
1500
1000
n
Vertically below an openable window, non-mechanical air inlet or any other
opening into a building with the exception of sub floor ventilation:
•
Space heaters up to 50MJ/h input
150
150
•
Other appliances up to 50 MJ/h input
500
500
•
Appliances over 50MJ/h input and up to 150 MJ/h input
1000
1000
•
Appliances over 150MJ/h input
1500
1500
* Unless appliance is certified for closer installation.
Notes:
1.
Prohibited area below electricity meter or fuse box extends to ground level.
2.
Where dimensions c, j or k cannot be achieved, an equivalent horizontal distance measured diagonally from the
nearest discharge point of the terminal to the opening may be deemed by the Technical Regulator to comply.
3.
Refer to AS/NZS 5601.1 clause 6.9.4 for restrictions on a flue terminal installed under a covered area.
4.
Refer to AS/NZS 5601.1 figure J3 for clearances required from a flue terminal to an LP gas cylinder. A flue
terminal is considered a source of ignition.
5.
For appliances not addressed above, acceptance should be obtained from the Technical Regulator.