ASSEMBLY

WARNING:

Failure to position parts in 

accordance with these diagrams 

and instructions and/or failure to 

use parts specifically approved for 

use with this appliance may result 

in property damage or personal 

injury.

Do not remove the data plates 

attached to the Outdoor Fire Pit 

Burner. These plates contain 

important information.

NOTICE: 

Installation and repair should 

be done by a qualified service 

person. The appliance should be 

inspected before use and at least 

once annually by a qualified service 

person. More frequent cleaning 

may be required as necessary. 

It is imperative that control 

compartment, burner ports and 

circulating air passageways of the 

appliance be kept clean.

CAUTION: 

New Lava Rock may pop or crackle 

when first heated. This should 

subside after 30 minutes to one 

hour or more of operation. Maintain 

safe distance during this time.

TO ASSEMBLE THE FIRE PIT

1.  Connect the Burner Assembly to the gas/propane 

supply using the supplied flex connector and following 

the instructions on page 8.

2.  Carefully leak test all connections following the 

procedure on page 8.

3.  Fill the burner pan evenly with burner media (crushed 

tempered glass for natural gas; volcanic rock for 

propane). Do not obstruct the pilot lighting port with 

burner media! Use burner media supplied by Paloform 

only!

4.  Follow the Initial Lighting Instructions on page 9. 

Make sure that the flame carries to all parts of the 

burner. Turn OFF the appliance and let it cool before 

proceeding to the next step.

5.  Evenly distribute decorative topping (river stones, 

crushed glass or lava rock) on top of burner media. An 

uneven or excessively thick layer of topping can result 

in an uneven flame.

6.  Do not cover pilot shield. Keep the lighting port open 

and free of media. Do not use any media not supplied 

by the manufacturer!

BURNER MEDIA

DECORATIVE TOPPING

LIGHTING PORT:

DO NOT OBSTRUCT

CORRECT FLAME APPEARANCE

Summary of Contents for BENTO 32 CIR-E-18

Page 1: ...NGER WARNING FOR OUTDOOR USE ONLY Installation and service must be performed by a qualified installer service agency or gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this...

Page 2: ...Gas Code ANSI Z223 1 NFPA 54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid...

Page 3: ...y licensed trades Space is tight Keep risers as low and compact as possible 6 MEDIA TOPPINGS Review correct placement p 6 7 PILOT ASSEMBLY BURNER RING BURNER MEDIA PAN PIPE ADAPTER FLEX CONNECTOR CONT...

Page 4: ...ut 69 000 BTU h 60 000 BTU h Inlet Pressure Min 4 5 W C 11 0 W C Inlet Pressure Max 10 5 W C 13 0 W C Orifice Size 18 37 Burner Ports 68 68 Port Size 1 8 1 8 Electrical 120V 15A Outdoor Receptacle Ded...

Page 5: ...5 BENTO 32 CORTEN FIRE PIT Electronic Ignition Installation Owner s Manual FIG 1 MINIMUM CLEARANCES TO COMBUSTIBLES REQUIRED CLEARANCES 72 72 8 13 BENTO 42 BENTO 32 0 CLEARANCE BELOW...

Page 6: ...f operation Maintain safe distance during this time TO ASSEMBLE THE FIRE PIT 1 Connect the Burner Assembly to the gas propane supply using the supplied flex connector and following the instructions on...

Page 7: ...RIOUS FILL TOPPING TRAY COVER BURNER MEDIA KEEP BELOW LID LINE BURNER MEDIA CRUSHED GLASS NG or LAVA ROCK LP FILL BURNER MEDIA TRAY COMPLETELY COVER BURNER RING VENTILATION HOLES DO NOT BLOCK CAUTION...

Page 8: ...use an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pr...

Page 9: ...qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service o...

Page 10: ...the manual gas control valve to the ON position 7 Plug the supplied 24 VAC AC adapter into a 110V power outlet 8 Connect the AC adapter to the AC input plug at the unit 9 Place Burner Assembly in Hous...

Page 11: ...rner at regular intervals at least twice a year Keep the burner and pilot area clean by vacuuming or brushing Make sure the burner porting and burner air openings are free of obstructions at all times...

Page 12: ...IGNITION PORT In the case of consistently windy conditions a protective glass barrier may be necessary 2 Ensure gas line is thoroughly bled 3 Ensure ventilation holes gaps are not obstructed Unit is...

Page 13: ...is clogged 4 Pilot valve lead is loose disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 11 or replace p...

Page 14: ...EPC same 1a Pilot Shroud CIR EPC same 2 Pilot Assembly PIL E 410 PIL E 410LP 3 18 Burner Ring CIR 18 BUR same 4 Burner Pan CIR 18 PAN same 5 Venturi CIR VEN 1 same 5a Air Shutter 6 Orifice FIT ORI 18...

Page 15: ...sing CIR E BOX same 2 Dual Solenoid Valve E VAL BASO w LP reg spring 3 3 8 x1 1 2 Nipple 4 3 8 Bulkhead Union 5 3 8 Street Elbow 6 Pilot Assembly PIL E 410 PIL E 410LP 7 Shrink fit Cord Grip 8 Ignitio...

Page 16: ...ILLUSTRATED PARTS LIST Wiring Diagram 1 2 3 4 5 10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 1 A CHASSIS GROUND PILOT PIL E...

Page 17: ...will at its option replace or repair the defective components at no charge to the original owner Paloform will also pay for reasonable labor cost incurred in replacing or repairing such components An...