background image

8

BENTO 32 CORTEN FIRE PIT Electronic Ignition | Installation & Owner's Manual

APPROVED FLEXIBLE GAS HOSE

A.G.A DESIGN-CERTIFIED MANUAL 

SHUTOFF VALVE WITH 1/8” NPT TAP

3” MINIMUM

CAP PIPE NIPPLE TEE JOINT

FROM GAS METER (5” W.C. 

TO 10.5” W.C. PRESSURE)

SEDIMENT TRAP

INSTALLATION REQUIREMENTS

Installation must include a manual shutoff valve, union, 

and plugged 1/8” NPT tap. Locate NPT tap within reach 

for test gauge hook up. NPT tap must be upstream from 

the appliance.

Apply pipe joint sealant lightly to male threads. This will 

prevent excess sealant from going into pipe. Excess 

sealant in pipe could result in a clogged burner injector.

Install sediment trap in supply line as shown below. 

Locate sediment trap where it is within reach for cleaning 

and trapped matter is not likely to freeze. 

A sediment trap prevents moisture and contaminants 

from entering the Outdoor Fire Pit controls. If a sediment 

trap is not installed, or is installed incorrectly, the unit may 

not work properly.

CHECKING GAS CONNECTION

       WARNING: Test all gas piping and connections 

for leaks after installing or servicing. Correct all leaks 

immediately.

       WARNING: Never use an open flame to check for 

a leak. Apply a mixture of liquid soap and water to all 

joints. Bubbles forming on joints while the gas is running 

indicate a leak. Correct all leaks at immediately.

Test Pressures in Excess Of 1/2 psi (3.5 kPa)

This appliance and its individual shutoff valve must be 

disconnected from the gas supply piping system during 

any pressure testing of that system at test pressures in 

excess of ½ psi (3.5 kPa).

Test Pressures Equal To or Less Than 1/2 psi (3.5 kPa)

This appliance must be isolated from the gas supply 

piping system by closing its individual manual shutoff 

valve during any pressure testing of the gas supply piping 

system at test pressures equal to or less than ½ psi (3.5 

kPa).

CONNECTING TO GAS SUPPLY

 WARNING:

A qualified service person must connect 

the appliance to the gas supply. Follow all 

local codes.

CAUTION: 

Use only new black iron or steel pipe. 

Internally tinned copper tubing may be 

used in certain areas. Use pipe of 1/2” 

diameter or greater to allow proper gas 

volume to Outdoor Fire Pit Burner. If pipe 

is too small, undue loss of pressure will 

occur.

INSTALLATION ITEMS NEEDED:

Before installing the Outdoor

Fire Pit, make sure you have all items 

listed bellow:

•  piping (check local codes)

•  sealant

•  manual shutoff valve

•  adjustable (crescent) wrench or pliers

•  sediment trap

•  tee joints

•  pipe wrench

                 

 

Summary of Contents for BENTO 32 CIR-E-18

Page 1: ...NGER WARNING FOR OUTDOOR USE ONLY Installation and service must be performed by a qualified installer service agency or gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this...

Page 2: ...Gas Code ANSI Z223 1 NFPA 54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid...

Page 3: ...y licensed trades Space is tight Keep risers as low and compact as possible 6 MEDIA TOPPINGS Review correct placement p 6 7 PILOT ASSEMBLY BURNER RING BURNER MEDIA PAN PIPE ADAPTER FLEX CONNECTOR CONT...

Page 4: ...ut 69 000 BTU h 60 000 BTU h Inlet Pressure Min 4 5 W C 11 0 W C Inlet Pressure Max 10 5 W C 13 0 W C Orifice Size 18 37 Burner Ports 68 68 Port Size 1 8 1 8 Electrical 120V 15A Outdoor Receptacle Ded...

Page 5: ...5 BENTO 32 CORTEN FIRE PIT Electronic Ignition Installation Owner s Manual FIG 1 MINIMUM CLEARANCES TO COMBUSTIBLES REQUIRED CLEARANCES 72 72 8 13 BENTO 42 BENTO 32 0 CLEARANCE BELOW...

Page 6: ...f operation Maintain safe distance during this time TO ASSEMBLE THE FIRE PIT 1 Connect the Burner Assembly to the gas propane supply using the supplied flex connector and following the instructions on...

Page 7: ...RIOUS FILL TOPPING TRAY COVER BURNER MEDIA KEEP BELOW LID LINE BURNER MEDIA CRUSHED GLASS NG or LAVA ROCK LP FILL BURNER MEDIA TRAY COMPLETELY COVER BURNER RING VENTILATION HOLES DO NOT BLOCK CAUTION...

Page 8: ...use an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pr...

Page 9: ...qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service o...

Page 10: ...the manual gas control valve to the ON position 7 Plug the supplied 24 VAC AC adapter into a 110V power outlet 8 Connect the AC adapter to the AC input plug at the unit 9 Place Burner Assembly in Hous...

Page 11: ...rner at regular intervals at least twice a year Keep the burner and pilot area clean by vacuuming or brushing Make sure the burner porting and burner air openings are free of obstructions at all times...

Page 12: ...IGNITION PORT In the case of consistently windy conditions a protective glass barrier may be necessary 2 Ensure gas line is thoroughly bled 3 Ensure ventilation holes gaps are not obstructed Unit is...

Page 13: ...is clogged 4 Pilot valve lead is loose disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 11 or replace p...

Page 14: ...EPC same 1a Pilot Shroud CIR EPC same 2 Pilot Assembly PIL E 410 PIL E 410LP 3 18 Burner Ring CIR 18 BUR same 4 Burner Pan CIR 18 PAN same 5 Venturi CIR VEN 1 same 5a Air Shutter 6 Orifice FIT ORI 18...

Page 15: ...sing CIR E BOX same 2 Dual Solenoid Valve E VAL BASO w LP reg spring 3 3 8 x1 1 2 Nipple 4 3 8 Bulkhead Union 5 3 8 Street Elbow 6 Pilot Assembly PIL E 410 PIL E 410LP 7 Shrink fit Cord Grip 8 Ignitio...

Page 16: ...ILLUSTRATED PARTS LIST Wiring Diagram 1 2 3 4 5 10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 1 A CHASSIS GROUND PILOT PIL E...

Page 17: ...will at its option replace or repair the defective components at no charge to the original owner Paloform will also pay for reasonable labor cost incurred in replacing or repairing such components An...

Reviews: