background image

2

BENTO 32 CORTEN FIRE PIT Electronic Ignition | Installation & Owner's Manual

SAFETY INFORMATION

 WARNINGS:

IMPORTANT: This appliance should 

be inspected before use and at least 

once annually by a qualified service 

person.

More frequent cleaning may be 

required as necessary. It is imperative 

that the control compartment, 

burners and circulating air 

passageways of the appliance be 

kept clean.

DANGER: Carbon monoxide 

poisoning can lead to death!

CARBON MONOXIDE POISONING:

Early signs of carbon monoxide 

poisoning resemble the flu, with 

symptoms including headache, dizziness, 

or nausea. If you experience these 

signs, the Fire Pit may not be working 

properly. Get fresh air at once! Have the 

Fire Pit serviced. Some people are more 

affected by carbon monoxide than others, 

including pregnant women, people with 

heart or lung disease or anemia, those 

under the influence of alcohol, and those 

at high altitudes.

NATURAL GAS AND PROPANE: 

To assist in detecting leaks, an odorant 

has been added to natural gas and 

propane. However, this odorant can fade, 

and gas may be present even though no 

odor exists. Make certain you read and 

understand all warnings. Keep this manual 

for reference. It is your guide to safe and 

proper operation of this appliance.

WARNING:

 Any modification to this appliance or its 

controls can be dangerous.

1.  This appliance, as supplied, is only for use with the 

type of gas indicated on the rating plate.

2.  When this appliance is connected to a fixed piping 

system, the installation must conform to local codes, 

or in the absence of local codes, to the National 

Fuel Gas Code, ANSI Z223.1/NFPA 54, or the 

International Fuel Gas Code.

3.  Keep the appliance area clear and free from 

combustible materials, gasoline and other flammable 

vapors and liquids

4.  Do not burn solid fuel in this appliance. Do not use 

this appliance to cook food or to burn paper or other 

objects.

5.  Children and adults should be alerted to the hazards 

of high surface temperatures and should stay away 

to avoid burns or clothing ignition.

6.  Clothing or other flammable materials should not be 

hung from the appliance, or placed on or near the 

appliance.

7.  Young children should be carefully supervised when 

they are in the area of the appliance.

8.  Do not use the appliance if any part has been under 

water. Immediately call a qualified service technician 

to inspect the appliance and to replace any part of 

the control system and any gas control which has 

been under water.

9.  Inspect the appliance before each use.

10. Turn the appliance off and let cool before servicing, 

installing, repairing or covering. Any guard or other 

protective device removed for servicing the appliance 

must be replaced prior to operating the appliance. 

Only a qualified service person should install, service, 

or repair the appliance.

HIGH ALTITUDE INSTALLATION

The appliance is certified for installations up to 4500’ 

(1372 m) above sea level. At this altitude range, no 

changes to the appliance are required. Please contact 

Paloform for information regarding installation above 

4500’ (1372 m).

LOCAL CODES

The installation of this appliance must conform with local 

codes, or in the absence of local codes, with the National 

Fuel Gas Code, ANSI Z223.1 • NFPA 54; National Fuel 

Gas Code; Natural Gas and Propane Installation Code, 

CSA B149.1; or Propane Storage and Handling Code, 

CSA B149.2, as applicable.

Summary of Contents for BENTO 32 CIR-E-18

Page 1: ...NGER WARNING FOR OUTDOOR USE ONLY Installation and service must be performed by a qualified installer service agency or gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this...

Page 2: ...Gas Code ANSI Z223 1 NFPA 54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid...

Page 3: ...y licensed trades Space is tight Keep risers as low and compact as possible 6 MEDIA TOPPINGS Review correct placement p 6 7 PILOT ASSEMBLY BURNER RING BURNER MEDIA PAN PIPE ADAPTER FLEX CONNECTOR CONT...

Page 4: ...ut 69 000 BTU h 60 000 BTU h Inlet Pressure Min 4 5 W C 11 0 W C Inlet Pressure Max 10 5 W C 13 0 W C Orifice Size 18 37 Burner Ports 68 68 Port Size 1 8 1 8 Electrical 120V 15A Outdoor Receptacle Ded...

Page 5: ...5 BENTO 32 CORTEN FIRE PIT Electronic Ignition Installation Owner s Manual FIG 1 MINIMUM CLEARANCES TO COMBUSTIBLES REQUIRED CLEARANCES 72 72 8 13 BENTO 42 BENTO 32 0 CLEARANCE BELOW...

Page 6: ...f operation Maintain safe distance during this time TO ASSEMBLE THE FIRE PIT 1 Connect the Burner Assembly to the gas propane supply using the supplied flex connector and following the instructions on...

Page 7: ...RIOUS FILL TOPPING TRAY COVER BURNER MEDIA KEEP BELOW LID LINE BURNER MEDIA CRUSHED GLASS NG or LAVA ROCK LP FILL BURNER MEDIA TRAY COMPLETELY COVER BURNER RING VENTILATION HOLES DO NOT BLOCK CAUTION...

Page 8: ...use an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pr...

Page 9: ...qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service o...

Page 10: ...the manual gas control valve to the ON position 7 Plug the supplied 24 VAC AC adapter into a 110V power outlet 8 Connect the AC adapter to the AC input plug at the unit 9 Place Burner Assembly in Hous...

Page 11: ...rner at regular intervals at least twice a year Keep the burner and pilot area clean by vacuuming or brushing Make sure the burner porting and burner air openings are free of obstructions at all times...

Page 12: ...IGNITION PORT In the case of consistently windy conditions a protective glass barrier may be necessary 2 Ensure gas line is thoroughly bled 3 Ensure ventilation holes gaps are not obstructed Unit is...

Page 13: ...is clogged 4 Pilot valve lead is loose disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 11 or replace p...

Page 14: ...EPC same 1a Pilot Shroud CIR EPC same 2 Pilot Assembly PIL E 410 PIL E 410LP 3 18 Burner Ring CIR 18 BUR same 4 Burner Pan CIR 18 PAN same 5 Venturi CIR VEN 1 same 5a Air Shutter 6 Orifice FIT ORI 18...

Page 15: ...sing CIR E BOX same 2 Dual Solenoid Valve E VAL BASO w LP reg spring 3 3 8 x1 1 2 Nipple 4 3 8 Bulkhead Union 5 3 8 Street Elbow 6 Pilot Assembly PIL E 410 PIL E 410LP 7 Shrink fit Cord Grip 8 Ignitio...

Page 16: ...ILLUSTRATED PARTS LIST Wiring Diagram 1 2 3 4 5 10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 1 A CHASSIS GROUND PILOT PIL E...

Page 17: ...will at its option replace or repair the defective components at no charge to the original owner Paloform will also pay for reasonable labor cost incurred in replacing or repairing such components An...

Reviews: