background image

17

BENTO 32 CORTEN FIRE PIT Electronic Ignition | Installation & Owner's Manual

WARRANTY INFORMATION

RETAIN FOR WARRANTY

MODEL: (circle one) 

Bento 32-E NG

   Corten

 

 

 

Bento 32-E LP

   Corten

   

SERIAL NO:

DATE PURCHASED:

Paloform’s priority is to meet or exceed your expectations with our products and service—we take pride in our products and 

unequivocally stand behind them. If your product has issues, we will work with you to make things right. 

This said, fires pit's are mechanical appliances that are installed in uncontrolled and unpredictable environments. For this 

reason it is critical that your unit be inspected by a qualified service technician regularly, dependent on use and site conditions, 

but at minimum once per year. This will ensure that it receives the type of general cleaning and maintenance that will maximize 

its performance and lifespan. Furthermore, there are various “wear” components which have a limited lifespan due to the fact 

that their function is to sustain extreme conditions. Over the functional life of your fire pit, you can expect that parts such as 

pilots, control devices and valves, may need to be replaced periodically. Materials such as cast concrete and Corten Steel are 

expected to weather naturally over their lifetime and changes in appearance are normal and do not constitute failure in the 

materials.

WARRANTY - This product is warranted to the original owner, subject to proof of purchase: 

Paloform warrants the components and materials in your appliance to be free from manufacturing and material defects for a 

period of one year from date of delivery. During this time, if any of the components in the appliance are found to be defective in 

materials or workmanship, Paloform will, at its option, replace or repair the defective components at no charge to the original 

owner. Paloform will also pay for reasonable labor cost incurred in replacing or repairing such components. Any products 

presented for warranty repair must be accompanied by a dated proof of purchase.

This Warranty will be void if:

•  the appliance is not installed by a qualified installer in accordance with installation instructions.

•  the appliance is not operated and maintained according to the operating instructions supplied with the appliance, including 

regular inspections by a qualified technician

•  the appliance is damaged by accident, neglect, misuse, abuse, alterations, negligence of others, including the installation 

thereof by unqualified installers, incidental or consequential damage

•  the appliance is partially or totally submerged under water for any length of time

This Warranty does not cover normal wear and tear, including but not limited to extraordinary environmental factors such as 

salt-saturated environments or extreme weather events.

All service work must be performed by an qualified service technician.

This warranty is expressly in lieu of other warranties, express or implied, including the warranty of merchantability of fitness 

for purpose and of all other obligations or liabilities. Paloform does not assume for it any other obligations or liabilities in 

connection with sale or use of the appliance. In states or provinces that do not allow limitations on how long an implied 

warranty lasts, or do not allow exclusion of indirect damage, those limitations of exclusions may not apply to you. You may also 

have additional rights not covered in the Limited Lifetime Warranty. Paloform reserves the right to investigate any and all the 

claims against this Warranty and decide upon method of settlement. For information about this warranty contact:

Paloform

888.823.8883

[email protected]

Summary of Contents for BENTO 32 CIR-E-18

Page 1: ...NGER WARNING FOR OUTDOOR USE ONLY Installation and service must be performed by a qualified installer service agency or gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this...

Page 2: ...Gas Code ANSI Z223 1 NFPA 54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid...

Page 3: ...y licensed trades Space is tight Keep risers as low and compact as possible 6 MEDIA TOPPINGS Review correct placement p 6 7 PILOT ASSEMBLY BURNER RING BURNER MEDIA PAN PIPE ADAPTER FLEX CONNECTOR CONT...

Page 4: ...ut 69 000 BTU h 60 000 BTU h Inlet Pressure Min 4 5 W C 11 0 W C Inlet Pressure Max 10 5 W C 13 0 W C Orifice Size 18 37 Burner Ports 68 68 Port Size 1 8 1 8 Electrical 120V 15A Outdoor Receptacle Ded...

Page 5: ...5 BENTO 32 CORTEN FIRE PIT Electronic Ignition Installation Owner s Manual FIG 1 MINIMUM CLEARANCES TO COMBUSTIBLES REQUIRED CLEARANCES 72 72 8 13 BENTO 42 BENTO 32 0 CLEARANCE BELOW...

Page 6: ...f operation Maintain safe distance during this time TO ASSEMBLE THE FIRE PIT 1 Connect the Burner Assembly to the gas propane supply using the supplied flex connector and following the instructions on...

Page 7: ...RIOUS FILL TOPPING TRAY COVER BURNER MEDIA KEEP BELOW LID LINE BURNER MEDIA CRUSHED GLASS NG or LAVA ROCK LP FILL BURNER MEDIA TRAY COMPLETELY COVER BURNER RING VENTILATION HOLES DO NOT BLOCK CAUTION...

Page 8: ...use an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pr...

Page 9: ...qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service o...

Page 10: ...the manual gas control valve to the ON position 7 Plug the supplied 24 VAC AC adapter into a 110V power outlet 8 Connect the AC adapter to the AC input plug at the unit 9 Place Burner Assembly in Hous...

Page 11: ...rner at regular intervals at least twice a year Keep the burner and pilot area clean by vacuuming or brushing Make sure the burner porting and burner air openings are free of obstructions at all times...

Page 12: ...IGNITION PORT In the case of consistently windy conditions a protective glass barrier may be necessary 2 Ensure gas line is thoroughly bled 3 Ensure ventilation holes gaps are not obstructed Unit is...

Page 13: ...is clogged 4 Pilot valve lead is loose disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 11 or replace p...

Page 14: ...EPC same 1a Pilot Shroud CIR EPC same 2 Pilot Assembly PIL E 410 PIL E 410LP 3 18 Burner Ring CIR 18 BUR same 4 Burner Pan CIR 18 PAN same 5 Venturi CIR VEN 1 same 5a Air Shutter 6 Orifice FIT ORI 18...

Page 15: ...sing CIR E BOX same 2 Dual Solenoid Valve E VAL BASO w LP reg spring 3 3 8 x1 1 2 Nipple 4 3 8 Bulkhead Union 5 3 8 Street Elbow 6 Pilot Assembly PIL E 410 PIL E 410LP 7 Shrink fit Cord Grip 8 Ignitio...

Page 16: ...ILLUSTRATED PARTS LIST Wiring Diagram 1 2 3 4 5 10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 1 A CHASSIS GROUND PILOT PIL E...

Page 17: ...will at its option replace or repair the defective components at no charge to the original owner Paloform will also pay for reasonable labor cost incurred in replacing or repairing such components An...