50
PA-5400 SERIES NEXT-GEN FIREWALL HARDWARE REFERENCE | PA-5400 Series Firewall Installation
©
2021 Palo Alto Networks, Inc.
Connect Power to a PA-5400 Series Firewall
The following topics describe how to connect power to a PA-5450 firewall. Before proceeding, read
Determine PA-5400 Series Firewall Power Configuration Requirements
to ensure that you understand the
available power options and that you provide enough power to the firewall based on your configuration.
After you power on the firewall, you can
View PA-5400 Series Firewall Power Statistics
.
Set Up a Connection to the Firewall
based on your desired boot mode prior to powering on
the firewall for the first time.
•
Connect AC or DC Power to a PA-5450 Firewall
Determine PA-5400 Series Firewall Power Configuration
Requirements
At least one active AC or DC power supply is required to operate a PA-5400 Series firewall. Factors that
can change your power requirements are the number of Networking Cards (NCs) and Data Processor Cards
(DPCs) used and your power redundancy requirement.
To determine the number of active power supplies required to operate the appliance, refer to
and locate your model and power input type and then locate the column that
coincides with the number of installed DPCs. Each power supply requirement in the table accounts for the
installation of 1 or 2 NCs. To provide full redundancy, install double the minimum number of power supplies
specified in the table. A fully redundant power configuration means that half of the installed power supplies
can fail and the appliance and installed NCs and DPCs will still function.
Table 1: PA-5400 Series Power Supply Chart
Front Cards Installed and Active Power Supplies Required
Model and Power Input
1 DPC
2 DPCs
3 DPCs
4 DPCs
5 DPCs
PA-5450 Firewall 110/120VAC
2
2
3
3
3
PA-5450 Firewall 240VAC or
-48VDC
1
1
2
2
2
All power supply requirements in the table above account for 1 or 2 NCs being installed in
the appliance.
You can find power information for hardware components in
PA-5400 Series Firewall Component Electrical
. To view power statistics on an active firewall, see
View PA-5400 Series Firewall Power
After you determine the power requirements for your firewall, see
Connect Power to a PA-5400 Series
and select the topic for your model and power type.
Connect AC or DC Power to a PA-5450 Firewall
The following procedure describes how to connect power to a PA-5450 firewall with either AC or DC
power supplies installed. The AC power supplies support 100 to 240VAC power input and the DC power