Replace a PA-5400 Series Firewall Front Slot
Card
The PA-5400 Series firewalls require one Management Processor Card, at least one Networking Card
(NC), and at least one Data Processor Card (DPC). The procedures to replace all of the front slot cards in a
PA-5400 Series firewall are identical.
•
Replace a PA-5400 Series Management Processor Card (MPC)
•
Replace a PA-5400 Series Networking Card (NC)
•
Replace a PA-5400 Series Data Processor Card (DPC)
•
PA-5400 Series Front Slot and Card States
•
PA-5400 Series Logical Card Slots
•
Replace a PA-5450 Front Slot Card in a High Availability (HA) Configuration
Replace a PA-5400 Series Management Processor Card (MPC)
Learn how to replace a MPC.
•
Replace a PA-5450 Management Processor Card (MPC)
Replace a PA-5450 Management Processor Card (MPC)
STEP 1 |
Put the provided ESD wrist strap on your wrist ensuring that the metal contact is touching your
skin. Then attach (snap) one end of the ground cable to the wrist strap and remove the alligator
clip from the banana clip on the other end of the ESD grounding cable. Plug the banana clip
end into one of the ESD ports located on the front of the appliance before handling ESD
sensitive hardware. For details on the ESD port location, see
.
STEP 2 |
Ensure that the PA-5450 is powered off and that the fans are not still spinning.
STEP 3 |
Push the front tabs on the MPC towards the center, prompting a click. This will cause ejector
handles on the front of the card to rotate outward and unlock the card.
STEP 4 |
Grip the front ejector handles and gently pull the card out of its slot.