ILP 25/33 Installation Manual
Rev. 1.4
- 30 -
Weld on Mount Plates (Verify):
Verify the following: One, F dimension has not changed. Two, bed
extension and platform are still squared prior to tack welding the mount plates,
Fig.23
. Three, gate
is operating as intended.
Do not power gate hard against bed extension while gate is only
tack welded in position.
Wooden Spacer
Chassis
Frame
Body Long Rail
"F" DIM.
Secondary
Jack
Primary
Jack
Weld on Mount Plates (Finalize):
After verification continue to 100% welding of the mount
plate to the vehicle frame and mount frame,
Fig.24
.
C
L
Right
Mount
Plate
Mount
Plate
Mount
Frame
1/4"
1/4"
Fig.23
Fig.24