ILF 33/44/55 Installation Manual
Rev 1.1
36
9
Electrical Installation
Any deviation from PALFINGER Liftgates’s recommended power setup
will void warranty and product
liability
unless you have a written confirmation by PALFINGER Liftgates that allows you to do specific
changes.
Prior to starting electrical installation insure that the liftgate batteries are fully charged. 12.6V
for Flooded Acid Batteries, and 12.8V for AGM Batteries. Charge batteries if necessary.
Never exceed rating of existing fuses located at the battery, control board and/or the pump and
motor which may result in serious damage to the equipment.
Never jump the 150 Amp circuit breaker at the batteries unless otherwise instructed by the
PALFINGER Liftgates
technical support team.
All connections should be heat shirk protected and all open ended terminals must be
replaced with closed end terminals or the open ends must be protected with heat shrink
tubing.
Never secure a cable in a way where it can make contact with other wiring, brake-, fuel- or air-
lines, or get pinched against other objects.
It is highly recommended to use 2 gauge wire throughout the electrical system when
connecting to batteries.
Do not splice battery cables unless otherwise instructed by the Palfinger LIftgates technical
support team.
All electrical cables and wires must secured with cable ties, hoses clamps, or other fasteners.
No wiring components rub on the frame, platform, or any other components while unit is in
operation or in storage.