MAIN MENU
Simply pressing on button P4 (MENU) you can scroll the set thermostat values, signalled by the flashing corresponding LED P1 / VALV / P2.
To modify the values, go to the thermostat value to modify:
s
Press P3(+) to increase the value
s
Press P2(+) to decrease the value
To store the change, wait approx. 5 seconds and scroll all parameters with the button P4(MENU)
Main menu parameters
Symbol
LED
Min
Factory
Max
Configuration
Thermostat P1 on probe S1
A04
P1
25
30
99
LQDOOFRQ¿JXUDWLRQV
T
hermostat VALV on probe S1
A05
VALV
25
45
99
CFG50 excluded
Thermostat VALV on probe
S
2
A15
VALV
25
50
99
only in CFG50
Thermostat P2 on probe S1
A06
P2
25
70
99
LQDOOFRQ¿JXUDWLRQV
Thermostat AUX on probe S2
A15
AUX
25
50
99
only in CFG 40
INSTALLER MENU
Only INSTALLERS or EXPERT PERSONNEL may access this menu, as if these parameters are changed the product may no longer be suitable for
the application in use.
s
To access the MENU press P1(ON/OFF) and P4(MENU) at the same time for approx. 5 seconds.
s
To scroll the parameter labels, use buttons P3(+) and P2(-)
s
To display the parameter value, press P4 (MENU)
s
To change the value, press the buttons P3(+) and P2(-) together with the button P4(MENU)
s
To display the parameter list again and store it, press P4 (MENU)
s
To exit, wait approx. 5 seconds.
,QVWDOOHUPHQXSDUDPHWHUV
08
6\PERO
Min
)DFWRU\ 0D[
PRODUCT configuration
-
CFG
10
Thermostat for activating the ALARM function on probe S1
°C
A 01
80
90
99
SAFETY thermostat on probe S1
°C
A 02
80
80
90
Thermostat for activating the “ICE” anti-freeze on probe S1
°C
A 03
4
6
8
ANTI-CONDENSATION thermostat on probe S1
°C
A 07
25
40
85
PUMP1 thermostat hysteresis on probe S1
°C
i 04
1
2
20
VALVE thermostat hysteresis on probe S1
°C
i 05
1
2
20
PUMP2 thermostat hysteresis on probe S1
°C
i 06
1
2
20
ANTI-CONDENSATION thermostat hysteresis on probe S1
°C
i 07
1
2
20
AUX thermostat hysteresis on probe S2 in CFG P13
VALVE thermostat hysteresis on probe S2 in IN CFG
°C
i 15
1
5
20
ANTIBLOCKING timer
h
t 01
1
168
255
ANTIBLOCKING pump activation time
sec
t 02
0
20
99
Safety enabling
n
P01
0
0
1
52