5.4.3 Housing with optional ventilation kit 680 m
3
/h
For existing wood inserts, there must be a compartment
under the wood insert base to house the fan. Its
dimensions must be as indicated in the
¿
gure
(Fig. 5.5 - 5.5.1)
5.4.4 Air intakes with optional ventilation kit 680 m³/h.
In addition to the combustion air intake (“C” -
¿
g. 5.6), the
following air intakes must be provided for the fan:
X
Room air intake to heating circuit fan, located laterally
to the cladding (diameter 15 cm) with grille.
Y
Room air intake (connected as (
X
(-5.6-)), or
alternatively connected to an adjacent room (with the
exception of the bathroom, kitchen, bedroom) (diameter
15 cm) with grille (-5.7-).
Depending on the solution adopted, during the dry test
installation it is advisable to mark the position of the air
intakes on both the cladding and the external wall.
•
The fan air intakes can be provided with an adjustable
closure shutter, and must be equipped with anti-insect
screens.
•
It is indispensable to clean
¿
lters or
¿
ne mesh grilles
periodically because they may become clogged.
6 AIR
CIRCULATION
There are three possible solutions to hot air
circulation
:
•
NATURAL CIRCULATION (STANDARD)
(supplied with the machine)
•
NATURAL CIRCULATION WITH HOOD
(with the Natural ventilation with hood kit)
•
FORCED CIRCULATION WITH HOOD
With the Centrifugal fan with adjustment unit kit and
Ventilation with hood kit.