39
00 477 0152 -04/2017 - PALAZZETTI - PN - I
TALY
Fig. 5.8.2
Fig. 5.9.1
ENGLISH
INSTALLATION
6.11
OPTIONAL FAN CONTROL UNIT KIT
The axial fans in the Appliance
can be turned on and
their speed adjusted with the relative control unit (Fig.
5.9.1).
SWITCHES FOR THE FANS
If the optional control unit is not installed,
À
ush mount a
switch for starting and stopping the fans,
¿
tted with fuses.
The electrical circuit features a minimum temperature
thermostat that lets the fans start only if the
¿
re is lit (which
occurs after 15-20 minutes depending on the size of the
¿
re) and the fans will stop when it is cold. The
Appliance
can also work without the fans on.
The control unit and all electrical parts must be installed
and connected by skilled personnel in compliance with
current standards. It must be possible to inspect and
remove the control unit and all the electrical parts for
maintenance or repairs.
6.12
THE “680” FAN KIT INCLUDING THE
CONTROL UNIT (OPTIONAL)
If instead you want to distribute the hot air following a more
complex ducting system, as indicated in point 5.4.2, you
will have to use the “680” fan with the whole system laid
out as explained below