INSTALLATION
6.1
OPTIONAL AIR DISTRIBUTION KIT
•
If the space between the upper pro
¿
le of Appliance and
the beam is at least 10 cm, the air outlet collars can be
mounted before installing Appliance.
•
On the contrary, drill a big enough hole on the
¿
replace’s
hood.
•
Fix the collars (
B
Fig. 5.6) with self-tapping screws after
having removed the plugs (
A
Fig.5.6)
6.2
AIR DISTRIBUTION IN AN ADJACENT ROOM
OR IN COUNTER HOOD:
This mode is peculiar to
Appliance
with
optional axial
fans
. Before recessing the
Appliance
the following has
to be done:
•
drill the walls and existing hood to allow passage and
application of the 14 cm diameter
À
exible pipes.
•
to ensure a correct
À
ow of air avoid ducts that are longer
than 2 metres (Fig. 5.4.2).
•
f the space between the upper part of the
Appliance
and
the lower pro
¿
le of the beam is less than 10 cm it will be
necessary to make a hole about 30 x 40 cm on the hood
to
¿
x the ducts later.
•
the vents on the hood or wall at a height of at least 1.80-2.00
m from the ground to prevent hot air hitting people.
6.3
DUCTED PIPES FOR HEATING SEVERAL
ROOMS (OPTIONAL KIT)
To heat more than one room the
Appliance
¿
replace can
be
¿
tted with
the optional “680” fan
and metal pipes for
distributing the air as follows:
•
À
exible aluminium pipe – maximum 2-3 m in length per
pipe
•
plain metal pipe or duct – up to 3+3 m in length on a
double duct; 6 m on just the one duct.
6.4
DOUBLE DUCT PIPING (FIG. 5.4.3 A)
Install a vent in the same room as the
¿
replace. The
second pipe can be used to carry hot air to the other
rooms in the house.