66/164
cod. 00 477 1480 - 12/2012 - Palazzetti - PN - Italy
USE AND MAINTENANCE
13.3.7 CLEANING THE loading SCREW
If the feed pipe clogs, that takes the pellets to the
combustion chamber, proceed as follows:
remove the protective grid from inside the box,
unscrewing the four cross-slotted screws with
a screwdriver;
remove the inspection plate stop (Fig. 8.3.1);
remove the inspection plate unscrewing the
black knurled knob (Fig. 8.3.2);
remove all pellet residuals from inside the feed
pipe with a screwdriver (Fig. 8.3.3).
= "
13.3.8 ;
This should be performed at least twice a year,
at the start of and half-way through winter, and in
any case whenever necessary (Fig.15.9). If there
are horizontal sections, check for and remove any
accumulated ash and soot before these block the
!
If not cleaned correctly, the stove may not operate
properly, with problems including:
- poor
combustion;
-
blackening of the glass;
-
blockage of the burn pot by ash and pellets;
-
accumulated ash and excessive fouling of the
heat exchanger, with a consequent decline in
!
Fig.15.9