ENGLISH
USE AND MAINTENANCE
10.8 FROST PROTECTION FUNCTION
2QO\LQFRQ¿JXUDWLRQ
A minimum temperature can be set below which the stove will switch on (outside of the set time bands, and only
if the timer is active). To set the “frost protection” temperature:
a) Use the arrow buttons
to go to the setup menu
and then press
;
b) Use the
button to select the password “7” and then press
WRFRQ¿UP
c) Select submenu
[9]
DQGFRQ¿UPE\SUHVVLQJ
;
d)
7KHYDOXHZLOOÀDVKFKDQJHLWXVLQJWKH
buttons (
OFF
;
3...20
°C);
e) Press
WRFRQ¿UPWKHVHWWLQJV
11
ALARM MANAGEMENT
If a malfunction occurs, the following procedure is activated:
1) audible alarm (beep);
2) one of the following system LEDs come on:
;
3) if the problem concerns an error, the stove will switch off.
Pressing and holding the “cancel” button
shows the error code on the display:
ERROR/
WARNING CODE
DESCRIPTION
POSSIBLE CAUSES
LED
E001
Faulty control panel
Control panel fault
E002
Remote control signal communication error
Control panel fault
E004
Communication error
Connection cable between board and control panel
interrupted or detached.
,IWKLVDSSHDUVZKHQFKDQJLQJFRQ¿JXUDWLRQLJQRUH
the error
E101
Failed ignition error
No pellets
Pellet quality
Faulty ignition system
Burn pot dirty
Problems with the heating system
Problems with the pump
E105
Pellet probe malfunction
Pellet probe disconnected or faulty
E108
*
Safety error
Door or hopper lid open
E109
Pressure error or thermal safety
Flue gas exhaust system dirty
Seal gaskets worn
,QVXI¿FLHQWFRPEXVWLRQDLU
Problems with overheating in the pellet hopper
E110
Temperature probe malfunction
Faulty air temperature probe
E111
Flue gas temperature probe malfunction
)DXOW\ÀXHJDVWHPSHUDWXUHSUREH
A001
Low pellet level
ico
Q
À
as
K
i
QJ
Pellets running out
A002
Scheduled maintenance warning
ico
Q
s
À
as
K
i
QJ
The stove periodically requires maintenance to be
SHUIRUPHGE\DTXDOL¿HGWHFKQLFLDQ
A007
Pressure sensor malfunction
ico
Q
À
as
K
i
QJ
Pressure sensor or board fault.
----
Clean stove
&RPEXVWLRQFKDPEHUEXUQSRWRUÀXHJDVH[KDXVW
system dirty.
Pressure measuring tubes detached or blocked.
Combustion air intake blocked.
----
Failed ignition error
No pellets; Faulty ignition heater; Worn gaskets;
Incorrect burn pot position
* Only for the models equipped with safety microswitches on the door or on the hopper lid.
After having checked the type of message, the alarm can be reset by pressing the on/
off button
for a few moments.
If the error code is “
E109
”, before resetting the alarm, manually reset the thermostat
located on the rear of the stove (Fig. 11.1)
t
K
is s
K
o
X
ld
E
e carried o
X
t
E\
a
Q
a
X
t
K
ori
]
ed
tec
KQ
icia
Q
.
Then the stove can be started again.
¿J
Summary of Contents for Ecofire Adagio
Page 2: ......
Page 4: ......
Page 16: ...16 cod 00 477 2290 04 2015 Palazzetti PN Italy USO E MANUTENZIONE USO E MANUTENZIONE ...
Page 29: ......
Page 30: ......
Page 42: ...42 cod 00 477 2290 04 2015 Palazzetti PN Italy USE AND MAINTENANCE USE AND MAINTENANCE ...
Page 55: ......
Page 56: ......
Page 81: ......
Page 82: ......
Page 94: ...94 cod 00 477 2290 04 2015 Palazzetti PN Italy EMPLOI ET ENTRETIEN EMPLOI ET ENTRETIEN ...
Page 107: ......
Page 108: ......
Page 120: ...120 cod 00 477 2290 04 2015 Palazzetti PN Italy USO Y MANTENIMIENTO USO Y MANTENIMIENTO ...
Page 133: ......
Page 134: ......
Page 135: ......