20
LED
Code
Smart View
Fault Code
Fault
Category
Possible Cause
Fault Clearance
13
F13101
1
This warning is set if any task has
between 10% and 20% of its stack
free
13
F13102
1
An internal logic supply rail has
gone out of range.
14
F14101
1
EMCY message received from
non-Sevcon node and anonymous
EMCY level is set to 1.
Check status of non-
Sevcon nodes on CANbus.
14
F14102
1
14
F14103
1
15
F15101
1
Vehicle service next due time has
expired (if supported). If support-
ed, service driveability profile will
activate.
Service vehicle and reset
service hours counter.
2
F22001
2
Valid direction selected with oper-
ator not seated or operator is not
seated for a user configurable time
in driver.
Must be seated with
switches inactive.
2
F22002
2
Both the forward and reverse
switches have been inactive simul-
taneously for greater than 200 ms.
Check vehicle wiring and
reset switches.
2
F22003
2
FS1 active for user configurable
delay without a direction selected.
Deselect FS1.
2
F22004
2
Any drive switch active at power
up.
Deselect all drive switches
2
F22005
2
FS1 active after a direction change
and FS1 recycle function enabled.
Deselect FS1.
2
F22006
2
Inch switch active along with any
drive switch active, seat switch
indicating operator present or
handbrake switch active.
2
F22007
2
Vehicle overloaded
Remove overload condition
2
F22008*
2
2
F22009*
2
2
F22010
2
Traction function inhibited using
traction inhibit switch.
Deselect traction inhibit.
2
F22011
2
Vehicle changed from traction
mode to pump mode (or vice-ver-
sa) when direction selected.
Deselect all drive switches.
2
F22012*
2
2
F22013*
2
2
F22014
2
Fault with momentary direction
selection switch.
Release momentary
direction switch
Fault Codes and Troubleshooting Chart (continued)
Summary of Contents for PC NXG Series
Page 1: ...INDUSTRIAL ELECTRIC VEHICLE PC NXG and PCT NXG Series April 2017 ...
Page 2: ......
Page 4: ......
Page 6: ......