![Pacific Power Source UPC-32 Operation Manual Download Page 89](http://html1.mh-extra.com/html/pacific-power-source/upc-32/upc-32_operation-manual_3149812089.webp)
SECTION 5
REMOTE OPERATION
79
5.5.2 METERED DATA QUERIES (continued)
:MEASure:CURRent:CREST1?
Query: metered current Crest Factor
Ф
A
Returns <0> to <1000>
:MEASure:CURRent:CREST2?
Query: metered current Crest Factor
Ф
B
Returns <0> to <1000>
:MEASure:CURRent:CREST3?
Query: metered current Crest Factor
Ф
C
Returns <0> to <1000>
:MEASure:POWer1?
Query: metered Kilowatts
Ф
A
Returns <0> to <1000> KW
:MEASure:POWer2?
Query: metered Kilowatts
Ф
B
Returns <0> to <1000> KW
:MEASure:POWer3?
Query: metered Kilowatts
Ф
C
Returns <0> to <1000> KW
:MEASure:KVA1?
Query: metered KiloVoltAmps
Ф
A
Returns <0> to <1000> KVA
:MEASure:KVA2?
Query: metered KiloVoltAmps
Ф
B
Returns <0> to <1000> KVA
:MEASure:KVA3?
Query: metered KiloVoltAmps
Ф
C
Returns <0> to <1000> KVA
:MEASure:PF1?
Query: metered power factor (KW/KVA)
Ф
A
Returns <0> to <1.0>
:MEASure:PF2?
Query: metered power factor (KW/KVA)
Ф
B
Returns <0> to <1.0>
:MEASure:PF3?
Query: metered power factor (KW/KVA)
Ф
C
Returns <0> to <1.0>
:FETCh[:WAVEform]:VOLT1?
:FETCh[:WAVEform]:CURRent1?
Query: metered waveform data (line-to-neutral voltage
only)
:VOLT1
for
Ф
A,
:VOLT2
for
Ф
B, and
:VOLT3
for
Ф
C
volts
:CURR1
for
Ф
A,
:CURR2
for
Ф
B, and
:CURR3
for
Ф
C
current
Returns a string of 512, NR2 type numbers, comma
delimited. Each waveform string is terminated by a semi-
colon. Only a single waveform may be queried in a
command.