FORM,<n>
sets Output Power Form of selected program
n
= <1>Single
Ф
, <2>Split
Ф
, or <3>Three
Ф
COUPLing,<s>
sets Output coupling of selected program
s
= <DIRECT> or <XFMR>
XFMRRATIO,<n.nn>
sets Output XFMR ratio (n.nn:1) of selected program
n.nn
= <0.01> to <5.11>
FREQuency,<n>
sets Output Frequency of selected program
n
= <:SOUR:FREQ:LIM:MIN> to <:SOUR:FREQ:LIM:MAX> Hz
VOLTage,<n>
sets Output VOLTAGE
Ф
A,B,C of selected program
n
= <0> to <150, or 150 x XFMRRATIO> Volts
VOLTage1,<n>
sets Output VOLTAGE
Ф
A of selected program
n
= <0> to <150, or 150 x XFMRRATIO> Volts
VOLTage2,<n>
sets Output VOLTAGE
Ф
B of selected program
n
= <0> to <150, or 150 x XFMRRATIO> Volts
VOLTage3,<n>
sets Output VOLTAGE
Ф
C of selected program
n
= <0> to <150, or 150 x XFMRRATIO> Volts
CURRent:LIMit,<n>
sets Output Current Limit of selected program
n
= <0> to <AMPS meter range> Amps
CURRent:PROTect:LEVel,<n>
sets Output Current level that triggers Current Protect mode
n = <0> to <AMPS meter range> Amps
CURRent:PROTect:TOUT,<n>
sets time that the Output Current must exceed the Current Protect
level before Current Protect disables the power source output.
n = <1> to <65535>, 1 = 100mSec.
PHASe2,<n>
sets Output Phase Angle B of selected program
n
= <0> to <359> degrees
PHASe3,<n>
sets Output Phase Angle C of selected program
n
= <0> to <359> degrees
WAVEFORM,<n>
sets Output Waveform
Ф
A,
Ф
B,
Ф
C of selected program
n
= <1> to <16>
WAVEFORM1,<n>
sets Output Waveform
Ф
A of selected program
n
= <1> to <16>
WAVEFORM2,<n>
sets Output Waveform
Ф
B of selected program
n
= <1> to <16>
WAVEFORM3,<n>
sets Output Waveform
Ф
C of selected program
n
= <1> to <16>