SECTION 5
REMOTE OPERATION
75
5.4.1 OUTPUT PARAMETERS (continued)
:[SOURce:]RAMP <t>
sets Output TRANSITION TIME of voltage and
frequency execution
t
= <0> to <300> seconds
minimum increment = 0.0002 Sec
:[SOURce:]FREQuency:LIMit:MAXimum <n>
sets Output Frequency max limit
n
= <20.00> to <5000> Hz
:[SOURce:]FREQuency:LIMit:MINimum <n>
sets Output Frequency min limit
n
= <20.00> to <5000> Hz
:[SOURce:]FREQuency:LIMit:RANGe?
Query: Returns
<min,max>,
minimum and maximum allowable frequency limits
:[SOURce:]VOLTage:LIMit:MAXimum <n>
sets Output Voltage maximum limit
n
= <0.00> to <600> VAC RMS
:[SOURce:]VOLTage:LIMit:MINimum <n>
sets Output Voltage minimum limit
n
= <0.00> to <600> VAC RMS
:[SOURce:]VOLTage:LIMit:RANGe?
Query: Returns
<min,max>,
minimum and maximum allowable voltage limit
:[SOURce:]VOLTage:INITial <b>
sets initial output voltage at power up
b
= <0> (0 volts) or <1> (last executed)
:[SOURce:]RANGe <n>
sets Output Range Control (for systems that support
Range Control)
n
= <0> to <4>. 0 sets Range Control to AUTO (
:[SOURce:]IMPEDance:STATE <b>
Enable or disable, Programmable Output Impedance
option
b
= <OFF>, <0> or <ON>, <1>
:[SOURce:]IMPEDance <z>
Sets the value of the Programmable Output Impedance
option
z
= varies based on the configuration and operational
mode of the power source
Use
:SOUR:IMPED:LIM:MIN?
and
:SOUR:IMPED:LIM:MAX?
to determine the available range
:[SOURce:]IMPEDance:LIMit:MINimum?
Query: returns
<min z>,
minimum allowable impedance
:[SOURce:]IMPEDance:LIMit:MAXimum?
Query: returns
<max z>,
maximum allowable impedance