4
300309-20
16”
Non-combustible fireplace
hearth
30 5/8”
21”
18”
8”
8”
*
Fireplace hearth requirements:
(Measured without the Insert)The non-combustible fireplace hearth must be raised
2” above an adjacent combustible floor and extend 16” in front and 8” beyond each side of the existing fireplace opening.
A non-combustible hearth that extends a minimum 23 1/2” in front of the fireplace opening may be flush to an adjacent
combustible floor.
Ember protection:
Combustible floor in front of the fireplace insert must be protected from hot embers by non-combustible material
extending 16” to the firing side and 8” to other sides of the unit.
**
Consult CAN/CSA-B365 Installation Code for Solid-Fuel-Burning appliances and equipment in Canada, and N.F.P.A.
211 Standard for chimneys, fireplaces, vents and Solid-Fuel-Burning appliances in USA.
16”
**
Non-combustible fireplace
hearth
Non-combustible floor
covering
2”
*
18”
22 1/4”