6.5"
24"
20.5"
2"
16"
3
300309-20
Safety
READ ALL INSTRUCTIONS BEFORE INSTALLING AND
USING THIS APPLIANCE.
We strongly recommend that smoke detectors be installed.
If smoke detectors have been previously installed, you may
notice that they are operating more frequently. This may be
due to curing of stove paint or fumes caused by accidentally
leaving the fire door open. Do not disconnect the detectors.
If necessary, relocate them to reduce their sensitivity.
SAFETY NOTICE: If this stove is not properly installed, a
house fire may result. For your safety, follow the installa-
tion directions. Consult local building or fire officials about
restrictions and installation inspection requirements in your
area.
Clearances
Masonry or Factory Built Fireplace
The minimum required clearances to surrounding combus-
tible materials when installed into a masonry or factory built
fireplace are listed below and in figure #1.
Minimum Clearances to Combustibles
(Measured From Insert Body)
Adjacent Sidewall .................... 20.5 in. (520 mm.)
Mantel ......................................... 24 in. (610 mm.)
Top Facing .................................. 24 in. (610 mm.)
Side Facing (1.5 in. extension) ... 6.5 in. (165 mm.)
Fig. # 1
Mantel or Top Facing
Side Facing
Fireplace
Hearth
Adjacent Wall