PEC017
5/3/2018
Page
17
of
105
N182
Page
Min
Default
Max
Units
Idle Timer Low Coolant Temperature
Override Threshold
2
30
260
°F
N183
Page
Min
Default
Max
Units
Idle Timer Engine Load Threshold
0
35
100
%
N184
Page
Min
Default
Max
Units
Idle Timer High Ambient Temp
Threshold
-40
80
490
°F
N185
Page
Min
Default
Max
Units
Idle Timer Low Ambient Temp
Threshold
-40
39
490
°F
N190
Page
Min
Default
Max
Units
Enable Idle Timer Reset from
Engine Load
OFF (0)
ON (1)
ON (1)
ON/OFF
* Requires
Enable Idle Timer Override from Engine Load (N191)
to be disabled
N191
Page
Min
Default
Max
Units
Enable Idle Timer Override from
Engine Load
OFF (0)
ON (1)
ON (1)
ON/OFF
* Requires
Enable Idle Timer Reset from Engine Load (N190)
to be disabled
* Not Available in PTO Mode
N197
Page
Min
Default
Max
Units
Enable Idle Timer Accelerator Pedal
Reset
OFF (0)
ON (1)
ON (1)
ON/OFF
N198
Page
Min
Default
Max
Units
Enable Idle Timer Service Brake
Reset
OFF (0)
ON (1)
ON (1)
ON/OFF
N199
Page
Min
Default
Max
Units
Enable Idle Timer Clutch Pedal
Reset
OFF (0)
ON (1)
ON (1)
ON/OFF