PEC017
5/3/2018
Page
53
of
105
PTO Control
Configuration
In-Cab
Throttle
Pedal
In-Cab
Set &
Resume
Switches
Remote
Throttle
Control
Remote
Set &
Resume
Switches
Stationary Cab
Station Switches
and Accelerator
2092049
1000294
Enabled Enabled Disabled Disabled
Parameter
Number
Parameter Description
Required Value
N079
Require Parking Brake for PTO Mode
ON
N102
Signal Source for Remote Main Switch
0
N306
Enable Engine Speed Control via TSC1
OFF
Table 12.4
– Stationary Cab Station Switches and Accelerator Configuration
PTO Control
Configuration
In-Cab
Throttle
Pedal
In-Cab
Set &
Resume
Switches
Remote
Throttle
Control
Remote
Set &
Resume
Switches
Stationary Remote
Station Switches
Only
2092052
1000295
Optional
(N307)
Disabled Disabled Enabled
Parameter
Number
Parameter Description
Required Value
N079
Require Parking Brake for PTO Mode
ON
Table 12.5
– Stationary Remote Station Switches Only
PTO Control
Configuration
In-Cab
Throttle
Pedal
In-Cab
Set &
Resume
Switches
Remote
Throttle
Control
Remote
Set &
Resume
Switches
Stationary Remote
Station Switches
and Accelerator
2092053
1000296
Optional
(N307)
Disabled Enabled Enabled
Parameter
Number
Parameter Description
Required Value
N079
Require Parking Brake for PTO Mode
ON
N306
Enable Engine Speed Control via TSC1
OFF
Table 12.6
– Stationary Remote Station Switches and Accelerator
Feature Options
1 Programmable Preset Engine Speeds in Remote PTO Mode