PEC017
5/3/2018
Page
18
of
105
EIST with PTO Mode
N186
Page
Min
Default
Max
Units
1
5
1092
MIN
Non-Programmable Parameters
Parameter Name
Number
Min/Max/Default/Units
EIST Low Oil Temperature Overrule
Limit
N195
DEFAULT = 30 °(F)
EIST Low Fuel Temperature Overrule
Limit
N196
DEFAULT = 23 °(F)
Note Regarding Preferred Settings
If the customer accepts the preferred EIST settings within Prospector, they will be
unable to make changes to the following parameters until they exceed the expiration
distance specified on the order:
Timer Setting Non-PTO Mode With Park Brake Set
Timer Setting PTO Mode w/o Park Brake Set
Expiration Distance
Reset EIST Timer Based on Engine Load
Low Ambient Temperature Overrule
High Ambient Temperature Overrule
Overrule EIST Timer Based on Engine Load
– No Shutdown
ON/OFF Requirements
EIST
ON
OFF
EIST Enabled
EIST Disabled
Vehicle Speed = 0 MPH
Vehicle Speed > 0 MPH
Outside Ambient Air Temperature Override
ON
OFF
Enable Ambient Overrule Temperature =
Yes
Enable Ambient Overrule Temperature =
No